P
ITOT
S
TATIC
K0553 Revision D
40
[EN] English
Pitot Static
When
Pitot Static
is selected on the dashboard, the resulting screen will clearly display whether
the ADTS is currently controlling the pressures at the Ps and Pt ports (CONTROL) or passively
measuring the pressures at the Ps and Pt ports (MEASURE).
The condition immediately after power up is always MEASURE, so as to protect any connected
systems.
To switch between the two modes, touch the related icon (1) at the bottom of the screen. See
Measure mode
The MEASURE mode screen displays real time Pitot Static parameter measurements (2) based on
the current pressures and rates of change (3) of pressures present at the Ps and Pt ports of the
ADTS or any connected aircraft systems. All ADTS pumping and pressure control functions are
inactive unless Autoleak protection is enabled.
This baseline Pitot Static information screen will typically be used to passively monitor the pres-
sure and leak rate status of the connected aircraft.
Figure 3-5: Measure mode screen - Single Channel