![GE 90-30 PLC Installation And Hardware Manual Download Page 439](http://html.mh-extra.com/html/ge/90-30-plc/90-30-plc_installation-and-hardware-manual_122953439.webp)
Index
GFK-0356Q
Index
Index-5
global data operation, 8-9
number in system, 8-7
status LEDs, 8-3, 8-5, 8-7
COM, 8-3, 8-5, 8-7
OK, 8-3, 8-5, 8-7
Genius bus scan, 8-8
Genius Comm. Module
(GCM), 8-2
Genius hand-held monitor, 8-6, 8-8
Genius I/O blocks, 8-8
Global data, 8-6, 8-9
receiving, 8-9
sending, 8-9
Ground bracket
CPU351, 352 figure, 2-15
Ground conductor installation, 2-11
Ground connections
equipment, 2-12
programming device, 2-13
safety and reference, 2-12
shield ground, 2-14
Ground wire
CPU363, 364 figure, 2-16
Grounding procedures, 2-11
Baseplate, 2-12
CPU shield, 2-14
Module shield, 2-14
Option modules, 2-16
Programmer, 2-13
system, 2-11
H
Hand-held monitor (Genius)
compatibility, 8-7
Hand-held monitor, Genius, 8-6
Hand-held programmer
CPU compatibility, 5-13
features of, 11-6
GBC configuration, 8-8
modes of operation, 11-6
Hand-held Programmer
function with FIP I/O nest, 8-12
Hand-Held Programmer
Cable data sheet, 10-33
general description, 11-5
Hand-held programmer cable
description of, 10-33
Hardware
load requirements, 12-12
Heat dissipation
calculating, 12-17
Help
from GE , 13-9
HHP, 11-5
Cable data sheet, 10-33
High capacity AC/DC power supply
illustration of, 4-4
overvoltage protection devices, 2-24
specifications, 4-5
High capacity DC power supply
specifications, 4-14
High Capacity DC power supply (24 VDC)
illustration of, 4-13
High speed counter, 8-23
Horner Electric, Inc., 11-8
Host CPU, 8-12
Hotline, PLC, 2-1
HSC
High Speed Counter, 8-23
I
I/O bus expansion cable
description of, 10-22
maximum cable distance, 10-23
maximum number in system, 10-23
I/O Bus Expansion cables
Application examples, 10-31
building, 10-22
wiring diagrams, 10-28
I/O bus termination information, 10-31
I/O cables for 32-point modules, 10-40
I/O expansion
bus termination, 3-12, 10-25
system connections, 10-31
I/O Expansion Bus cables, 3-10
I/O faceplate, H-3
I/O interface cables
for 32-point modules, 10-42, 10-49, 10-57
for Power Mate APM modules, 10-45
I/O link interface module
slave, 8-24
I/O link master module, 8-25
compatibility, 8-26
restart pushbutton, 8-26
serial port, 8-26
I/O module
Figure, standard density, 7-3
I/O Module
Relay protection, 7-4
I/O modules
32-point figure, 7-5
32-point wiring figure, 7-6
basic types, 7-1
inserting a module, 2-3
installing a terminal board, 2-5
number in FIP Nest, 8-12
removing a module, 2-4
removing a terminal board, 2-6
Wiring 32-point modules, 7-6
wiring to modules, 2-18
I/O Modules
32-point features, 7-4