IC693CBL329/330/331/332/333/334 Cables
24-Pin I/O Faceplate Connector to Terminal Block Connector
Note:
These cables replace obsolete cables IC693CBL321/322/323. The
obsolete cables had straight connectors. These replacement cables have
right-angle connectors to reduce the clearance space required in front of
the PLC. They use the same pin-outs as the obsolete cables.
Description
These cables all have a right-angle 24-pin connector on each end. They are identical except for
connector orientation (right side and left side types) and cable length. The difference in connector
orientation is to allow them to work with the dual-connector type of 32-point I/O modules. These
cables are wired pin-to-pin (that is, pin A1 to pin A1, pin A2 to pin A2, etc.). Similar cables are
available in a 3 meter length that have a right angle connector on one end and stripped leads on the
other (see the data sheet for the IC693CBL327/328 cables for further information).
Figure 10-40. IC693CBL329/330/331/332/333/334 Cables
Note
Each conductor in these 24-conductor cables has a current rating of 1.2 Amps. If
using these cables with a 16-point Output module with a higher output current
rating, you must use the lower value of 1.2 for the maximum load current rating .
If you have field devices that require more than 1.2 Amps, do not use a TBQC
assembly. Use the standard Terminal Board instead.