D-4
C60 Breaker Protection System
GE Multilin
D.1 OVERVIEW
APPENDIX D
D
Parameter in control direction
File transfer
Type identifier and cause of transmission assignments
(station-specific parameters)
In the following table:
•Shaded boxes are not required.
•Black boxes are not permitted in this companion standard.
•Blank boxes indicate functions or ASDU not used.
•‘
X
’ if only used in the standard direction
<110> := Parameter of measured value, normalized value
PE_ME_NA_1
<111> := Parameter of measured value, scaled value
PE_ME_NB_1
4
<112> := Parameter of measured value, short floating point value
PE_ME_NC_1
<113> := Parameter activation
PE_AC_NA_1
<120> := File Ready
F_FR_NA_1
<121> := Section Ready
F_SR_NA_1
<122> := Call directory, select file, call file, call section
F_SC_NA_1
<123> := Last section, last segment
F_LS_NA_1
<124> := Ack file, ack section
F_AF_NA_1
<125> := Segment
F_SG_NA_1
<126> := Directory (blank or X, available only in monitor [standard] direction)
C_CD_NA_1
TYPE IDENTIFICATION
CAUSE OF TRANSMISSION
NO.
MNEMONIC
1
2
3
4
5
6
7
8
9
10
11
12
13
20
to
36
37
to
41
44
45
46
47
<1>
M_SP_NA_1
X
X
X
X
X
<2>
M_SP_TA_1
<3>
M_DP_NA_1
<4>
M_DP_TA_1
<5>
M_ST_NA_1
<6>
M_ST_TA_1
<7>
M_BO_NA_1
<8>
M_BO_TA_1
<9>
M_ME_NA_1
PERIODIC, CYC
L
IC
BAC
KGR
O
U
ND SCAN
SPO
NT
AN
EO
US
INIT
IALIZ
E
D
REQUEST O
R
RE
QUESTE
D
ACT
IVATION
ACT
IVATION C
O
NF
IRMAT
ION
DEACT
IVATI
O
N
DEACT
IVATI
O
N C
O
N
F
IRMAT
ION
ACT
IVATION T
E
RMINAT
ION
RETU
RN INF
O
CAUSED BY L
O
CAL C
M
D
FIL
E
TRA
N
SFER
INT
E
R
R
OGA
T
ED BY GROUP <NUMBER
>
REQUEST BY GROU
P
<N> COUN
TER REQ
UNKNO
WN TYPE
IDENTI
FICATION
UNK
NOWN
CAUSE OF T
RANSMISSION
UNKNO
WN
CO
MMON ADDRESS OF ADS
U
UNK
NOWN IN
FORMAT
ION
OBJEC
T
ADDR
UNK
NOWN IN
FORMAT
ION
OBJEC
T
ADDR
Summary of Contents for C60
Page 2: ......
Page 4: ......
Page 11: ...GE Multilin C60 Breaker Protection System xi TABLE OF CONTENTS INDEX ...
Page 12: ...xii C60 Breaker Protection System GE Multilin TABLE OF CONTENTS ...
Page 32: ...1 20 C60 Breaker Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 50: ...2 18 C60 Breaker Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Page 128: ...4 30 C60 Breaker Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 394: ...9 4 C60 Breaker Protection System GE Multilin 9 1 FAULT LOCATOR 9 THEORY OF OPERATION 9 ...
Page 516: ...D 10 C60 Breaker Protection System GE Multilin D 1 OVERVIEW APPENDIXD D ...
Page 528: ...E 12 C60 Breaker Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...