B-12
C60 Breaker Protection System
GE Multilin
B.4 MEMORY MAPPING
APPENDIX B
B
1A40
...Repeated for Source 2
1A80
...Repeated for Source 3
1AC0
...Repeated for Source 4
1B00
...Repeated for Source 5
1B40
...Repeated for Source 6
Source Power (Read Only) (6 modules)
1C00
Source 1 Three Phase Real Power
-1000000000000 to
1000000000000
W
0.001
F060
0
1C02
Source 1 Phase A Real Power
-1000000000000 to
1000000000000
W
0.001
F060
0
1C04
Source 1 Phase B Real Power
-1000000000000 to
1000000000000
W
0.001
F060
0
1C06
Source 1 Phase C Real Power
-1000000000000 to
1000000000000
W
0.001
F060
0
1C08
Source 1 Three Phase Reactive Power
-1000000000000 to
1000000000000
var
0.001
F060
0
1C0A
Source 1 Phase A Reactive Power
-1000000000000 to
1000000000000
var
0.001
F060
0
1C0C
Source 1 Phase B Reactive Power
-1000000000000 to
1000000000000
var
0.001
F060
0
1C0E
Source 1 Phase C Reactive Power
-1000000000000 to
1000000000000
var
0.001
F060
0
1C10
Source 1 Three Phase Apparent Power
-1000000000000 to
1000000000000
VA
0.001
F060
0
1C12
Source 1 Phase A Apparent Power
-1000000000000 to
1000000000000
VA
0.001
F060
0
1C14
Source 1 Phase B Apparent Power
-1000000000000 to
1000000000000
VA
0.001
F060
0
1C16
Source 1 Phase C Apparent Power
-1000000000000 to
1000000000000
VA
0.001
F060
0
1C18
Source 1 Three Phase Power Factor
-0.999 to 1
---
0.001
F013
0
1C19
Source 1 Phase A Power Factor
-0.999 to 1
---
0.001
F013
0
1C1A
Source 1 Phase B Power Factor
-0.999 to 1
---
0.001
F013
0
1C1B
Source 1 Phase C Power Factor
-0.999 to 1
---
0.001
F013
0
1C1C
Reserved (4 items)
---
---
---
F001
0
1C20
...Repeated for Source 2
1C40
...Repeated for Source 3
1C60
...Repeated for Source 4
1C80
...Repeated for Source 5
1CA0
...Repeated for Source 6
Source Energy (Read Only Non-Volatile) (6 modules)
1D00
Source 1 Positive Watthour
0 to 1000000000000
Wh
0.001
F060
0
1D02
Source 1 Negative Watthour
0 to 1000000000000
Wh
0.001
F060
0
1D04
Source 1 Positive Varhour
0 to 1000000000000
varh
0.001
F060
0
1D06
Source 1 Negative Varhour
0 to 1000000000000
varh
0.001
F060
0
1D08
Reserved (8 items)
---
---
---
F001
0
1D10
...Repeated for Source 2
1D20
...Repeated for Source 3
1D30
...Repeated for Source 4
1D40
...Repeated for Source 5
1D50
...Repeated for Source 6
Energy Commands (Read/Write Command)
1D60
Energy Clear Command
0 to 1
---
1
F126
0 (No)
Source Frequency (Read Only) (6 modules)
1D80
Frequency for Source 1
---
Hz
---
F003
0
1D82
Frequency for Source 2
---
Hz
---
F003
0
1D84
Frequency for Source 3
---
Hz
---
F003
0
1D86
Frequency for Source 4
---
Hz
---
F003
0
Table B–9: MODBUS MEMORY MAP (Sheet 5 of 50)
ADDR
REGISTER NAME
RANGE
UNITS
STEP
FORMAT
DEFAULT
Summary of Contents for C60
Page 2: ......
Page 4: ......
Page 11: ...GE Multilin C60 Breaker Protection System xi TABLE OF CONTENTS INDEX ...
Page 12: ...xii C60 Breaker Protection System GE Multilin TABLE OF CONTENTS ...
Page 32: ...1 20 C60 Breaker Protection System GE Multilin 1 5 USING THE RELAY 1 GETTING STARTED 1 ...
Page 50: ...2 18 C60 Breaker Protection System GE Multilin 2 2 SPECIFICATIONS 2 PRODUCT DESCRIPTION 2 ...
Page 128: ...4 30 C60 Breaker Protection System GE Multilin 4 3 FACEPLATE INTERFACE 4 HUMAN INTERFACES 4 ...
Page 394: ...9 4 C60 Breaker Protection System GE Multilin 9 1 FAULT LOCATOR 9 THEORY OF OPERATION 9 ...
Page 516: ...D 10 C60 Breaker Protection System GE Multilin D 1 OVERVIEW APPENDIXD D ...
Page 528: ...E 12 C60 Breaker Protection System GE Multilin E 2 DNP POINT LISTS APPENDIXE E ...