1.

S

AFETY

P

RECAUTIONS

WARNING!

FAILURE TO FOLLOW THESE SAFETY PRECAUTIONS AND INSTALLATION

INSTRUCTIONS COULD RESULT IN INJURY OR DEATH AND

/

OR DAMAGE TO PROPERTY AND

EQUIPMENT

.

Appropriately licensed and competent personnel only should install the automation equipment.

The operators are designed specifically to open and close sliding gates or doors and should not be used for any
other purpose.

Before commencing installation, read through this installation manual.

Check that the operator and controls are in new condition and have not been damaged in transit.

Check the gate or door and it’s associated support posts

and walls to protect against shearing, compression and

other various traps which could cause serious injury or death. Take into consideration the general installation and
surrounding environment.

Check the gateposts or mounting structure has the necessary strength and rigidity to support the operator and the
load of the opening and closing gate motion.

CAUTION!

Always incorporate the appropriate Photo Electric Cells, Induction Loops and any other safety devices to
protect both equipment and personnel. Extra caution should be employed when using operator in auto
close mode.

Display any necessary signs to indicate any danger areas and automatic operation of the gate or door.

The operators are not designed to be used in any hazardous areas or areas subject to flooding etc.

All electrical connections and wiring must be performed with AS/NZS 3000-2007 as the guidelines. (Or its
counterpart for other countries outside of Australia and New Zealand)

WARNING! ELECTRICITY CAN KILL

The manufacturer of the automation equipment is not responsible for the damage which may be caused to either
the operator, gate or door and any other person or equipment when: -

o

Wrong or poor installation practices were performed.

o

No or inadequate safety devices were used.

o

Either the surrounding structure or the gate or door strength and rigidity was not sufficient for the task in
hand.

o

Inefficient locking devices were employed.

o

Poor maintenance on the equipment.

o

Any other circumstances beyond the manufacturers control.

Isolate power before attempting any maintenance, qualified personnel only to carry out maintenance

Only original spare parts are to be used should there be a requirement for them.

Keep loose clothing and hands clear of the gate whilst in operation or potentially able to be operated.

The installer should provide all information concerning the use of the automation equipment as well as
instructions regarding the manual override and maintenance procedures to the users of the system.

Summary of Contents for 630P I Range

Page 1: ...allation and Maintenance Manual Sliding Gate Operators Inbuilt Models GDS 450P I 630P I Range Made in Australia from Australian quality imported components MOVITRAC B N14870 A B N 62 059 806 405 Oct 2...

Page 2: ...etween the rack teeth and Pinion wheel Once the rack is fixed move the gate and sight the rack moving over the pinion wheel check that most of the pinion wheel meshes with the rack Make sure rack runs...

Page 3: ...omatically fully close During this commissioning the PE beam and Door inputs are not required Once the gate is commissioned gate has fully closed the gate distance is in the memory of the inverter the...

Page 4: ...tion Details 6 11 Electrical Cabling Mechanical Installation Plan view of installation Operator dimensions Electrical Connections Variable Speed Drive Unit Variable Speed Drive Unit Key Pad Operation...

Page 5: ...necessary signs to indicate any danger areas and automatic operation of the gate or door The operators are not designed to be used in any hazardous areas or areas subject to flooding etc All electric...

Page 6: ...elded cable if over 8m runs 4 INSTALLATION DETAILS After reading the previous sections in this manual and having checked for suitable installation proceed as follows Electrical Cabling A suitably rate...

Page 7: ...7 Plan View of Installation Operator Dimensions...

Page 8: ...N22 setting see notes that follow Open Initialise Input This input is used to commission the drive and also used to open and close the gate Door input The door input is a safety function due to the op...

Page 9: ...eypad fully clockwise is maximum time 120 seconds No PE auto close meaning the gates will not close even if the PE cell beam is broken and made again No Multi user meaning the auto close time can be o...

Page 10: ...or start up function has been pre set in the factory and should not need altering Parameter Settings Par Nxx Pt 39 Input Status Pt 59 Output Status Pt 80 Fault memory records the previous faults which...

Page 11: ...lly open onto the open stop The gate will then automatically start closing at slow speed do not interrupt this auto commissioning cycle as it is determining the gate opening distance CAUTION Ensure ve...

Page 12: ...nderstanding what each input does will help to clear or rectify any problem relating to the input To see the status of the inputs proceed to parameter 39 via the keypad refer to section on keypad oper...

Page 13: ...us run did not find the limit at the Correct position 7 flashes Gate fully open and pedestrian input held so gate will not close 8 flashes F 08 speed monitoring fault motor can t get to desired speed...

Page 14: ...13 13 14 6...

Page 15: ...very tight If when turning the knurled knob clockwise and It just spins either try spinning it clockwise with more force to release it off of the hexagonal retaining nut or hold the nut with one hand...

Page 16: ...dvertently Gate rolls freely when in manual Gate wheels and guide rollers in good condition Gate stops in good condition and not loose Gate rack is tight correct clearances between pinion wheel rack G...

Page 17: ...tances i If no proof of date of purchase can be produced ii If the product has been used in a manner beyond its design parameters iii If the product is tampered with or repaired by personnel not autho...