10
The diagram below (Figure 2) corresponds to what is shown on the keypad of the SEW variable speed drive
(this keypad is removable).
Figure 2.
Function Factory Settings
Acceleration ramp time
5 sec
Deceleration ramp time
4 sec
Maximum speed
4000 rpm (For 750's = 640mm/sec, for 550's = 490mm/sec)
Opening Speed
3640 rpm (For 750's = 580mm/sec, for 550's = 440mm/sec)
Opening and closing slow speed 600 rpm (For 750's = 100mm/sec, for 550's = 75mm/sec)
Closing Speed
3000 rpm (For 750's = 480mm/sec, for 550's = 360mm/sec)
The motor start-up function has been pre-set in the factory and should not need altering
Parameter Settings
Par
Nxx
Pt 39
Input Status
Pt 59
Output Status
Pt 80
Fault memory (records the previous faults which occurs with the inverter)
Pt 136
PE stop time (0.5 s)
N11
Opening speed (3640 rpm)
N13
Closing speed (3000 rpm)
N21
When set to formulae and powered off and on will reinitialise the gate
N22
Pedestrian opening position (% of full opening position max 80%)
N23
Opening and closing slow speed (600 rpm)
Pt 400
Gate counter, maximum 5000 (500,000 operations) Note. 100 gate
operations will be recorded as 1 on the inverter counter).
Pt 401
Internal serial number for recalibration
Pt 450
low current setting (usually 60 %)
Summary of Contents for 630P I Range
Page 7: ...7 Plan View of Installation Operator Dimensions...
Page 14: ...13 13 14 6...