Sliding-gate operators

BX704AGS

BX704ALS

BX708AGS BX708RGS

BX708ALS

INSTALLATION MANUAL

FA01310-EN

EN

English

Summary of Contents for BX708ALS

Page 1: ...Sliding gate operators BX704AGS BX704ALS BX708AGS BX708RGS BX708ALS INSTALLATION MANUAL FA01310 EN EN English...

Page 2: ...2 Manual FA01310 EN 02 2020 CAME S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions 2 3 1 2 3 1...

Page 3: ...e entire site properly to prevent unauthorised personnel from entering especially minors In case of manual handling have one person for every 20 kg that needs hoisting for non manual handling use prop...

Page 4: ...ly follow these brief disposal guidelines DISPOSING OF THE PACKAGING The packaging materials cardboard plastic etc can be disposed of easily as solid urban waste separated for recycling Before dismant...

Page 5: ...ice and mechanical limit switches for sliding gates weighing up to 800 kg that are up to 14 m in length 801MS 0021 BX704ALS Operator complete with control board with programming display built in radio...

Page 6: ...on of the original instructions Description of parts Operator 1 Cover 2 Front cover 3 Gearmotor 4 Capacitor 5 Mechanical limit switch 6 Anchoring plate 7 Control board holder 8 Control board 9 Limit s...

Page 7: ...board for connecting the gearmotor 3 Terminal board for connecting the transformer 4 Control board fuse 5 Terminal board for connecting control and safety devices 6 Accessories fuse 7 Terminal board f...

Page 8: ...y consumption with the RGP1 W module 0 8 0 8 0 8 0 8 0 8 Power W 560 520 560 520 530 Capacitor F 12 20 12 20 80 Current draw mA 2 7 2 5 2 7 2 5 4 5 Colour RAL 7024 RAL 7024 RAL 7040 RAL 7040 RAL 7024...

Page 9: ...n ambient temperature of 20 C as stated in EN standard 60335 2 103 MODELS BX704AGS BX708AGS BX704ALS BX708ALS BX708RGS Cycles hour no 17 17 17 17 17 Consecutive cycles no 6 6 6 6 6 Standard reference...

Page 10: ...230 V and outdoors use H05RN F cables compliant with 60245 IEC 57 IEC when operating indoors use H05VV F cables compliant with 60227 IEC 53 IEC For power supplies up to 48 V you can use FROR 20 22 II...

Page 11: ...fitted on the left Preliminary operations Dig a hole for the foundation frame Set up the corrugated tubes needed for the wiring coming out of the junction pit Use 40 mm corrugated tubes to connect th...

Page 12: ...ate in the iron cage The tubes must pass through the existing holes 2 1 UNI 5739 12 X 70 M12 Position the anchoring plate taking note of the measurements shown in the drawing If the gate does not have...

Page 13: ...changed at any time and without notice Translation of the original instructions Remove the nuts from the screws Insert the electrical cables into the tubes until they protrude by about 600 mm Setting...

Page 14: ...the operator foundation frame Lift the operator by 5 10 mm from the plate by adjusting the threaded feet to allow for any adjustments that may need to be made between the rack and pinion 5 10 Fastenin...

Page 15: ...ing Open and close the gate manually Adjust the pinion rack coupling distance using the threaded feet vertical adjustment and the holes horizontal adjustment The weight of the gate must not bear down...

Page 16: ...chanical limit switches 1 Open the gate 2 Insert the opening limit switch tab in the rack The spring must trigger the microswitch 3 Fasten the opening limit switch tab using the grub screws supplied 1...

Page 17: ...able glands to connect the devices to the control panel One of these must be used exclusively for the power supply cable 1 Cable glands on the board holder Power supply Make sure the mains power suppl...

Page 18: ...3 6 5 4 7 1 White cable 2 Black cable 3 Red cable 4 Blue cable 5 Purple cable 6 Orange cable 7 To vary the motor torque move the corresponding Faston terminal to one of the four positions from 1 minim...

Page 19: ...Control device NO contact PARTIAL OPENING function 6 Control device NO contact OPEN CLOSE step by step or OPEN STOP CLOSE STOP sequential function 7 Antenna with RG58 cable S1GND A B 3 2 1 5 6 4 7 Saf...

Page 20: ...at any time and without notice Translation of the original instructions DIR DELTA S photocells Standard connection DIR DELTA S photocells Connection with safety test See function F5 safety devices tes...

Page 21: ...ns indicated below F54 Opening direction Set the gate opening direction F1 Total stop Stop the gate and exclude automatic closing Use a control device to resume movement A3 Travel calibration Start th...

Page 22: ...ter each opening and closing command F5 Safety devices test OFF Default 1 CX 2 CY 4 CX CY Hold to run With the function active the operator stops moving opening or closing when the control device is r...

Page 23: ...utomatic closing after partial opening Set the time before automatic closure is activated after a partial opening command has been performed The function does not work if any of the safety devices are...

Page 24: ...15 Closing slowdown point Set the closing slowdown start point as a percentage of total travel This function appears only if the Encoder function is active F38 Closing slowdown point 5 to 30 Default...

Page 25: ...1 to 255 RSE speed Set the remote connection system communication speed on the RSE port F63 RSE speed 0 1200 bps 1 2400 bps 2 4800 bps 3 9600 bps 4 14400 bps 5 19200 bps 6 38400 bps default 7 57600 bp...

Page 26: ...default 5 seconds New user Register up to a maximum of 250 users and assign a function to each one The operation can be carried out by using a transmitter or another control device The boards that man...

Page 27: ...code 3 TW key block Motor type Set the type of gearmotor installed A1 Motor type 1 BX704 2 BX708 Travel calibration Start the travel self learning This function appears only if the Encoder function i...

Page 28: ...ORY ROLL card DISCONNECT THE MAINS POWER SUPPLY TO THE LINE 1 Insert the MEMORY ROLL card into the corresponding connector on the control board 2 Press the Enter button to access programming 3 Use the...

Page 29: ...ailure error E4 Service test failure error E7 Operating time error E8 Open release hatch error Check that the accessories fuse is not blown E9 Obstacle detected during closing E10 Obstacle detected du...

Page 30: ...to the control board which will be set as the MASTER For information on connecting the electrics for the devices and accessories please see the ELECTRICAL CONNECTIONS section RSE A B GND UTP CAT5 max...

Page 31: ...the system is not used for long periods of time e g for installations at sites with seasonal closures disconnect the power supply When the power supply is reconnected check the system is working corr...

Page 32: ...E S p A The contents of this manual may be changed at any time and without notice Translation of the original instructions CAME S p A Via Martiri della Libert 15 31030 Dosson di Casier Treviso Italy T...