background image

Automatic Garage Door

Operator

Installation Instruction

Summary of Contents for Roll-A-Door RC-1

Page 1: ...Automatic Garage Door Operator Installation Instruction ...

Page 2: ...vals and the necessary adjustments made if required DO NOT disengage the Door Opener to manual operation with children persons or any other objects including motor vehicle within the doorway Install the wall switch or wall mounted transmitter in a LOCATION POSITION where the garage door is visible and out of reach of children The Garage door must be WELL BALANCED Sticking or binding doors must be ...

Page 3: ...hoto Electric Beam if this mode is selected otherwise the door will not operate SAFETY AUTO RUN TIME If the Opener does not complete its cycle within thirty seconds the Opener will stop if opening and reverse back open if closing automatically PHOTO ELECTRIC BEAM OPTIONAL The Opener has an input for a Photo Electric Beam to be connected for extra safety protection And use of the Auto Close Mode MA...

Page 4: ... connected to the Opener by wire cable The monitor indicates the status of the door for example if the door is moving or is opened or closed etc The door can also be controlled from the monitor unit 18 O S C Input is for connect ing the wired Wall Switch optional extra 19 P E SHUNT The shunt has to be removed when connecting a Photo Electric Beam 20 ENGAGE DISENGAGE HANDLE when pulled down and rel...

Page 5: ...RED 5 AUTO CLOSE BUTTON WHITE 6 RESET BUTTON 7 O S C BUTTON YELLOW 8 CLOSE LIMIT ADJUST SCREW RED 9 OPEN LIMIT ADJUST SCREW GREEN 10 CLOSE LIMIT CAM RED 11 OPEN DRIVE BUTTON GREEN 12 OPEN LIMIT RED 13 OPEN LIMIT CAM GREEN 14 FORCE MARGIN SET BUTTON 15 P E INPUT 16 EXTERNAL RECEIVER INPUT 17 SECURALIGHT INPUT 18 O S C INPUT 19 P E SHUNT 20 ENGAGE DISENGAGE HANDLE 5 ...

Page 6: ... DRIVE UNIT 1 FOUR CHANNEL TRANSMITTER PTX 4 2 HOLDER PTX 4 1 BATTERY 12 VOLTS 2 WEIGHT BARS NOT INCLUDED IN SOME COUNTRIES 2 SCREWS M4 x 25mm 4 SCREWS 6 x 25mm 2 PLASTIC WALL PLUGS 2 INSTALLATION MANUAL 1 6 SEQUENCE OF INSTALLATION ...

Page 7: ...a force of 10 kg 22 lbs 2 FIXING OF DOOR WEIGHT BARS Move the door manually to the mid open position Place the weight bars equally apart on the bottom rail of the door and secure them with the fasteners provided see Fig 3 Check the operation of the door again If the door feels heavy it may require extra tension to be added to the door springs Refer to the door Installation manual from manufacturer...

Page 8: ...eck that Step 3 was completed Carefully loosen and remove the right hand door shaft U bolt 5 Make sure that the door supporting prop is secure While the door is supported remove the right hand door mounting bracket from wall 6 Remove the Drive Assembly from packaging Try and rotate the drive gear by pushing on the fork If the gear does not rotate the manual mode has to be selected To select pull o...

Page 9: ...anticlockwise direction the green limit cam Fig 11 until the cam clicks the open limit switch 3 Move the door down by hand to the desired closed position 4 Rotate by hand in a clockwise direction the red limit cam Fig 12 until the cam clicks the close limit switch 5 Connect power lead from the Drive Assembly into a general purpose power outlet installed by a licensed electrical contractor Turn the...

Page 10: ...equal to approximately 10 mm of door travel NOTE If the door has not reached the desired limit position by more then 30 mm then it is recommended that the red limits cam be adjusted again before the red fine adjustment screw is adjusted 6 2 SETTING LIMITS FOR LEFT HAND INSTALLATION 1 With the Drive Assembly in manual mode see Fig 13 move the door up by hand to the desired open position 2 Remove th...

Page 11: ...hen 30 mm it is recommended that the green limits cam be adjusted again before the green fine adjustment screw is adjusted CLOSE LIMIT ADJUSTMENT Press in and hold the Red Close button fig 15 The door should start closing Release the Red Close button when the door reaches the desired closed limit stop position If the Red LED see Fig 15 is illuminated and the desired limit position has been reached...

Page 12: ...th the pressure you can change as below 7 2 TO INCREASE FORCE PRESSURE 1 Press and hold the Force Margin Set button 14 Fig 16 2 While holding down button 14 press the green Open button 11 The green LED will illuminate each time the green open button is pressed to indicate that the force pressure is being increased If the green LED flashes continuously when the open button is being pressed this ind...

Page 13: ...mitters 8 1 STORING THE TRANSMITTERS CODE 1 Press and hold the blue Door Code button on the Control Panel button 2 FIG 18 2 Press the button one of four on the Transmitter you would like to use to control the door for approximately two seconds FIG 18 Pause for two seconds Press the same button again on the Transmitter for approximately two second 3 Release the blue Door Code button 2 4 Press the T...

Page 14: ...rate the door The door should not respond 10 2 DELETING ALL STORED TRANSMITTER CODES 1 Turn the Power Off to the Drive Unit 2 Press and hold the blue Door Code button 2 FIG 21 on the Control panel 3 Turn the Power On again while holding the Blue Door Code button until the Coding LED illuminates Release the blue Door Code button 2 All the stored codes including the Courtesy Light Codes should now b...

Page 15: ...in curs an obstruction not from the P E while closing the door will re open and not auto close After the setting of the auto close mode whenever the door is in the open position the open limit green LED will flash to indicate that the auto close mode is in operation SETTING AUTO CLOSE TIME 1 Press in and hold the Auto Close Time button 5 FIG 25 2 While holding in the Auto Close Time button press t...

Page 16: ... TRAVEL STOPPED FLASHING FLASHING DOOR OBSTRUCTED WHEN OPENING FLASHING BEEPS ON AND OFF DOOR OBSTRUCTED WHEN CLOSING FLASHING BEEPS ON AND OFF DOOR OVERLOADED FLASHES 10 TIMES BEEPS ON AND OFF DOOR AND OPENER REQUIRE A SERVICE FLASHING BEEPS ONCE AT START OF ANY CYCLE DOOR AND OPENER APPROACHING OVER LOAD BEEPS FOR DURATION OF TIME APPROACHING OVERLOAD DOOR HAS APPROACHED THE OVERLOAD THREE TIMES...

Page 17: ...Door Drum Wheel OPENER MAXIMUM OPEN ING OR CLOSING RUN TIME 30 seconds RECEIVER TYPE UHF 433 92 MHz AM Receiver Receiver Code Storage Capacity 27 X 4 Button Transmitter Codes TRANSMITTER Frequency Coding Type Number of Code Combinations Code Generation Battery Voltage 433 92 MHz Hopping Code Over 4 29 Billion Hopping Codes Non linear Encryption Algorithm 12 Volts MOTOR TYPE Permanent Magnet Direct...

Page 18: ...tructions step 8 1 Extend aerial wire Replace battery 9V Door does not close fully Limit micro switch incorrectly adjusted Re adjust limit switch refer installation instruction step 6 Door does not open fully Limit micro switch incorrectly adjusted Re adjust limit switch refer installation instruction step 6 Lights malfunction Globe blown Replace with 24V DC 15 watts Festoon globe Globes keep blow...

Page 19: ...PARTS LIST 19 ...

Page 20: ...eturned to the supplier The defect is not caused by misuse negligence or accident This warranty must be returned by post to P O Box 124116 Alrode 1451 or faxed to 011 864 4286 duly completed Proof of purchase is provided Transmitter batteries and light bulbs are excluded from this warranty Duro Pressings Pty Limited accepts no further liability whatsoever in relation to any loss or damage third pa...