11
Selecting a Function
To select a function use the up/down arrow keys to select corresponding symbol for desired function.
An LED will light up the symbol and the display will show the programmed settings for that function.
Setting Function Values
Having selected the desired function; to enter or change a setting press the enter key. The display will flash.
A value for the function can now be entered or changed using the up/down arrow keys.
To confirm the value for the desired function press the enter key, this will set the value, then press the out button,
this will return you to the previous screen.
Gate Direction Set-Up
It is important that the gate is set up to operate correctly for the opening and closing cycles.
When the gate is closing a minus sign will be displayed on the screen when monitoring the RPM
On first pulse to open/commission the gate should always open first
If the operation is not as above, two motor wires need to be swapped over.
Commissioning
Tighten knurled knob at back of slider, very firmly by hand so gate will drive.
Power up board and with gate in the half way position, press transmitter or manual control switch (manufacturer
has provided a push button for open/closing/commissioning next to PLC inverter) so operator drives gate. (Note.
for commissioning, a momentary pulse is all that is required)
The first pulse must always open the gate, if it does not, then turn off the power and reverse 2 of the motor wires.
Allow the gate to fully open onto the open stop. The gate will then automatically start closing at slow speed; do
not interrupt this auto commissioning cycle as it is determining the gate opening distance.
CAUTION!
Ensure vehicles and personnel do not get in the way of the moving gate as both the
photoelectric cells and door inputs are bypassed during commissioning.
Once the gate reaches the fully closed position the invertor will automatically switch the power off to the motor.
The photoelectric/safety devices and door switch wiring will now need to be operational in order for the operator
to function.
Install cover onto operator with 4 fixing screws and close manual release door.
Press the transmitter or operate the access control, the gate will fully open at slow speed to confirm the gate
opening distance.
Once the gate has reached the fully open position, the operator is now ready to operate at full speed
A potentiometer has also been provided, which is found under the cover of the invertor, which can be rotated to
adjust the gate operation pre-warning time (clockwise = minimum time = 0 second, and anticlockwise =
maximum time = 5 seconds).
Press the transmitter or manual control switch to now test the normal operation, i.e. ramp up, run at fast speed,
ramp down and then slow speed into the open and closed stops.
PLEASE NOTE: Each time the gate operator power is turned off or the manual release door is opened, the gate
will run at slow speed to allow the controller to recalculate its position.
Check that all safety devices work as designed.
Provide full details to the owner concerning the operation and relevant maintenance and disconnection details in
the event of a power failure.
Summary of Contents for 630P I Range
Page 7: ...7 Plan View of Installation Operator Dimensions...
Page 14: ...13 13 14 6...