7
CyScan Positioning System • Installation and Maintenance Guide r1.1
GCS
GCS
To mount the CyScan PSU:
The CyScan PSU must be securely mounted within
one metre of the CyScan Sensor position.
1 Prepare a suitable site for the PSU and
pre-drill pilot holes for the mounting screws
according to the template provided in
Appendix 3.
2 Remove the PSU lid and insert four M6 x
30 stainless steel cap head screws through
the mounting holes at the four corners of
the PSU enclosure.
To mount the CyScan Data Converter
The CyScan Data Converter must be securely mounted in the vicinity of the CyScan
notebook computer.
1 Prepare a suitable site for the Data Converter and pre-drill pilot holes for the
mounting screws according to the template provided in Appendix 4.
2 Remove the Data Converter lid and insert four M4 x 20 stainless steel cap head
screws through the mounting holes at the four corners of the Data Converter
enclosure.