15/46
EN
4.5 BRIEF DESCRIPTION MTLX – GAS SUPPLY PANEL FOR ONE CYLINDER
With the gas supply panel type MTLX an industrial, non-toxic and non-corrosive gas or gas mixture, which is
stored inside gas cylinder or bundle with over pressure. This over pressure is reduced from maximum 300
bar to tubing pressure (10 bar, 20 bar, 40 bar, 100 bar).
A relief valve at pressure regulator secures the panel with its outlet pressure against incorrect pressure rising
at the outlet due to leakage in regulator seat.
The real inlet and outlet pressure of the panel is displayed at the pressure gauges. There is the possibility to
use contact gauges for inlet and outlet pressure. If the panel has the opportunity for inert gas purging, this
can be done before initial start-up to remove contaminates. Furthermore it is possible to depressurize the
high pressure side before cylinder is changed.
The described system is mounted on a stainless steel plate. Due to plate dimensions all components are
protected against damage inside of package, during transport and in mounted condition. The split design of
plate enables to mount the component easy and with less weight.
The hole in the front plate enables to change the gauge without disassembly of the complete panel. At the
ground plate at both sides are holes to connect the cylinder hoses with carabiner hook. To connect ground-
ing you can find screw at the ground plate.
The development, construction and production testing is according to the following standards:
•
regulators- ISO 7291
•
valves- ISO 10297
•
gauges EN 837-1
•
mechanical explosion prevention of complete panel- ISO80079-36; IEC 60079-32-1; TRGS 727
4.6 BRIEF DESCRIPTION MTLT – GAS SUPPLY PANEL FOR THREE CYLINDERS
With the gas supply panel type MTLT an industrial, non-toxic and non-corrosive gas or gas mixture, which is
stored inside gas cylinder or bundle with over pressure. This over pressure is reduced from maximum 300
bar to tubing pressure (10 bar, 20 bar, 40 bar, 100 bar).
At this panel the user can switch manually between three high pressure gas cylinders with three process gas
valves. It is possible that three or two of the gas cylinders or bundles emptying coincident. Check valves at
each high pressure inlet avoid that the gas cylinders or bundles refill each other. A relief valve at pressure
regulator secures the panel with its outlet pressure against incorrect pressure rising at the outlet due to leak-
age in regulator seat.
The real inlet and outlet pressure of the panel is displayed at the pressure gauges. There is the possibility to
use contact gauges for inlet and outlet pressure. If the panel has the opportunity for inert gas purging, this
can be done before initial start-up to remove contaminates. Furthermore it is possible to depressurize the
high pressure side before cylinder is changed.
The described system is mounted on a stainless steel plate. Due to plate dimensions all components are
protected against damage inside of package, during transport and in mounted condition. The split design
of plate enables to mount the component easy and with less weight. The hole in the front plate enables to
change the gauge without disassembly of the complete panel. At the ground plate at both sides are holes
to connect the cylinder hoses with carabiner hook. To connect grounding you can find screw at the ground
plate.
The development, construction and production testing is according to the following standards:
•
regulators- ISO 7291
•
valves- ISO 10297
•
gauges EN 837-1
•
mechanical explosion prevention of complete panel- ISO80079-36; IEC 60079-32-1; TRGS 727