7/46
EN
DANGER!
•
Gases can be life threatening!
Gases can supersede the oxygen in air. This can result in death by asphyxiation. Oxygen produces a
strongly oxidizing effect.
Therefore:
•
Sufficient ventilation is absolutely essential.
•
Installation only through certified company.
•
Observe ATEX-directive
ATTENTION!
•
Risk of injury from environment!
There can be malfunctions on component due to condensation and/ or icing.
Therefore:
•
Observe suitable temperatures.
•
Protect component from liquids from outside
•
Protect component from dust from outside
•
Protect component from weather conditions
•
Grounding has to be mounted properly
WARNING!
•
Risk of injury from using oil and grease!
Oil and grease must never be used in gas regulating systems. Oil and grease are highly inflammatory and
can react violently to certain pressurized gases.
Therefore:
•
Never use oil and grease
WARNING!
•
Risk of injury from residual energy stored in the system!
If handled incorrectly, pressurized components can move uncontrollably and cause severe injury. If han-
dled incorrectly or defective, pressurized components can leak gas under high pressure and cause severe
or even fatal injuries.
Before starting work with these components:
•
Installation only through certified company.
•
Always wear protective goggles when working.
•
Make sure the equipment is depressurized. Also make sure the residual energy is discharged.
•
Always ensure that gas cannot leak unintentionally.
•
Make sure that defective components that are pressurized during operation are immediately replaced by
trained staff.
WARNING!
•
Danger of accident!
Due to wrong installation there can be serious or even mortal injuries.
Therefore:
•
During installation the component should be kept safe
•
Never throw the component
Pressurised components are only for intended use.
If there are mechanical damages at tubing or components the whole system has to be put in a safe condition.
Affected area has to be blocked. Troubles which could influence safety, have to be eliminated through qualified
staff or supplier.
Especially with gases failure in pressure regulator could happen. Indications for defective regulator is no flow
or immediately rising outlet pressure. In this case system has to be shut-off and the relevant department for
maintenance has to be informed. Never close exhaust piping.