GA-02.035-EN-30.05.17
Page 5 of 46
gACC-499E/U Communication unit
gACC-499E_U_Manual_EN.doc
2.
Construction
2.1
Build-up
2.2
DIP-Switch
No.
Function
1 - On/Off
ON = Operating mode
Should be switched ON at normal operating mode!!
2 - No Sleep
ON = Disable sleep mode, the device will not go to sleep.
Should be switched OFF at battery operating mode!!
3 - LEDs On
ON = Status display on.
Should be switched OFF at battery operating mode!!
4 - Test mode
ON = Activate test mode
Should be switched OFF at normal operating mode!!
5 - Config 1
ON = Encoder operating mode
OFF = gAVC 1200 operating mode
6 - Config 2
Can be used to activate Log Level 0. This function can only be activated by
restarting the device after setting the switch.
7 - Encoder On
ON = Interface gAVC 1200 or Encoder on.
Should be switched ON at normal operating mode!!
8 - MU Power
ON = Power supply to EVCD enabled. (By externally powered EVCD)
Should be switched OFF at battery operating mode!!
PA-Klemmen
Antenna connection
Connector USB
configuration cable
DIP-Switch
(See below for
description)
Status display (LED)
SIM card
Terminals intrinsically
safe side. ( For
connection details see
below)
PA-Terminals
Removable dividing
wall
Battery connector 2.1
Battery connector 1.1
Fuse power supply
EVCD (mains power
supply only)
Summary of Contents for gACC-499E/U
Page 41: ...GA 02 035 EN 30 05 17 Page 41 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...
Page 42: ...GA 02 035 EN 30 05 17 Page 42 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...
Page 43: ...GA 02 035 EN 30 05 17 Page 43 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...
Page 44: ...GA 02 035 EN 30 05 17 Page 44 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...