gAvilar gACC-499E/U Manual Download Page 1

 

 
 
 
 

 

 

 

 

gACC-499E/U

 

 

 

Communication Unit for Encoder/gAVC 1200 

 

 

Manual 

Rev. 30.05.2017 

 

 

Please visit our website for the most recent version of this document www.gAvilar.nl

 

Summary of Contents for gACC-499E/U

Page 1: ...gACC 499E U Communication Unit for Encoder gAVC 1200 Manual Rev 30 05 2017 Please visit our website for the most recent version of this document www gAvilar nl ...

Page 2: ...056 21 7 2 8 The readout with configuration file IEC 62056 21 for gAVC 1200 9 2 9 The readout with configuration file IEC 62056 21 for Encoder 9 2 10 Explanation of the config file 10 2 11 The configuration program 14 2 12 Configuration read out 15 2 13 The hidden functions 16 2 15 Reading the archive cache 25 2 16 Internal caching 26 2 17 The Test Mode 26 2 18 Status check 26 3 0 Firmware update ...

Page 3: ... U 31 5 2 4 The dividing wall 31 5 2 5 Inserting the SIM card 31 5 2 6 Scheme Zener Barrier 32 5 2 7 Type plate 32 5 3 Repairs 33 5 4 The absorption pack 33 5 5 Pressure relief valve 33 6 0 The clock 34 6 1 Setting time locally 34 6 2 Setting time remotely 34 6 3 Setting time using the IEC62056 21 protocol 36 7 0 Meter exchange 37 7 1 Gas meter exchange 37 7 2 gAVC 1200 exchange 37 7 3 Battery exc...

Page 4: ...lied completely configured whereby the SIM card can be placed if requested by the customer The connection of the unsafe side is at the top of the Zener barrier performed by a plug connection The intrinsically safe outputs and terminals for the potential equalizing are located at the bottom so in the standard version in the terminal compartment of the housing The gACC 499E U can be used for several...

Page 5: ...r operating mode OFF gAVC 1200 operating mode 6 Config 2 Can be used to activate Log Level 0 This function can only be activated by restarting the device after setting the switch 7 Encoder On ON Interface gAVC 1200 or Encoder on Should be switched ON at normal operating mode 8 MU Power ON Power supply to EVCD enabled By externally powered EVCD Should be switched OFF at battery operating mode PA Kl...

Page 6: ...el 4 10 Pulse signal Signal line only possible with Safety Barrier channel 4 Connection Encoder or gAVC 1200 or Pulse Encoder gAVC 1200 Puls 1 NAMUR 3 UniWire B klem XP2 9 GND 2 NAMUR 4 UniWire A klem XP2 10 Pulse signal The PA terminals are to be connected to the PA connection of the installation This can be done by using 4mm2 yellow green wire or by using 2 wires of 1 5mm2 2 5 Power supply 2 5 1...

Page 7: ...conducted 2 6 Modem Configuration The configuration of the required information can be done by using a simple XML file which determines which data in which format should be sent This requires a configuration program which can be used to configure the modem locally and remotely For local configuration of the modem a special USB config cable is available 2 7 The configuration IEC 62056 21 To read ou...

Page 8: ...f the modem is in sleep mode the config cable must be plugged in the socket in order to activate it The modem will now come out sleep mode and will become active At least 3 LEDs have to be on before a value can be written For battery modems this can be done by setting DIP switch 3 to ON Make sure that DIP switch 3 is back in the OFF position before placing the cover This is to save battery power T...

Page 9: ...r 97 97 0 valuetype ALRACT1 multiplier 1 unit billingchannel identifier 1 13 0 0 valuetype VBZlastMonth multiplier 1 unit m3 billingchannel identifier 23 2 0 valuetype VNlastMonth multiplier 1 unit m3 protocol uptime hourstart 18 minutestart 00 minutesduration 30 upaftercallin 5 daylight y NoIntermediateGSM n dual1 2 9 The readout with configuration file IEC 62056 21 for Encoder dual2 swversion re...

Page 10: ...t parameter ensures that summertime is applied device The type of device is opened name gprs003 The name of the device type gAVC This is the type of modem set for a gAVC 1200 key_ 789 The key is the password of the gAVC 1200 for writing data timesync Y Time synchronization is disabled or with Y enabled fullsynctimediff Y With fullsynctimediff Y unlimited time changes can be made With N this is max...

Page 11: ...onth Vn index end of month 06 00 hour 1 m3 The status information of the gAVC 1200 concerns the current status information The units for temperature and pressure can be adjusted from K and mbar to C and bar The IEC62056 21 will be automatically adjusted after changes the units Channel OBIS code Parameter Factor Unit A5 0 41 0 0 T Gas temperature 1 C A6 0 42 0 0 PABS Gas pressure 1 bar B5 0 41 0 0 ...

Page 12: ...should preferably be done shortly before the read out takes place in order to have the cache complete during read out The daylight parameter ensures that summertime is applied device The type of device is opened name gprs003 The name of the device type CLKTENC This is the type of modem set for a encoder temperature and pulse timesync Y Time synchronization is disabled or with Y enabled fullsynctim...

Page 13: ...month 06 00 hour 1 m3 The units for temperature and pressure can be adjusted from K and mbar to C and bar The IEC62056 21 will be automatically adjusted after changes the units This is irrelevant for the encoder application because there are no meter readings Channel OBIS code Parameter Factor Unit A5 0 41 0 0 T Gas temperature 1 C A6 0 42 0 0 PABS Gas pressure 1 bar B5 0 41 0 0 T Gas temperature ...

Page 14: ...st be ticked With Reset pw the Config password can be reset This requires the existing password Mobile network Enter operator and when required a PIN For GPRS connection enter an APN The server socket is used in case of a GPRS socket connection With home the provider of the placed SIM card is used as default Server 1 The password is the P1 password for IEC62056 21 communication The server type mus...

Page 15: ...he Baud rate field The activation of the password is arranged in the configuration file During read out the user will be prompted whether to save the configuration file or not At the end of the read out the below dialog appears This dialog shows a The field strength in dB b Software version and compilation date c Device time current time d TC65 version number e The setting of the DIP switches x no...

Page 16: ...sed by clicking on the icon in the left corner of the configuration program The here shown functions can be executed both locally by using a config cable and also remotely via a modem about GACCconfig Under Settings there is a dialogue in which a choice can be made to hide the passwords and to activate summer winter transitions This last function only affects the local readout of the cache memory ...

Page 17: ... set index value can be entered for the logging of impulses of e g a gas meter With this function the index value of the gas meter can be synchronized with the commissioning of the gACC 499E U Set time At Set time the time of the connected PC can be written in the gACC 499E U It is important to check if the time of the PC is the correct time before this is written into the gACC 499E U For more clo...

Page 18: ...E_U_Manual_EN doc Get measurement Encoder At Get measurement can be checked in case of direct communication with an encoder if the encoder function is operating correctly Both A telegram and B telegram are read The index value of the gas meter The information of the B telegram ...

Page 19: ... direct communication with an gAVC 1200 if the communication with the gAVC 1200 is functioning correctly The clock of the gAVC 1200 is read and when the UniWire is connected correctly it will reply with an Init OK Also the B telegram of the connected gas meter will be read 37 bytees are read The communication with the gAVC is OK The information of the B telegram ...

Page 20: ...y displayed as well as the ICT Inter Character Time At Functions the date can be read and or set de time can be read and or set billing data can be retrieved and an interval for a load profile can be set in order to read it afterwards The default interval which is displayed by the configuration program is always the latest current day The program locks the buttons while performing the last chosen ...

Page 21: ...which is determind for each calendar month and will be applied The correction may vary per month because a different clock deviation can occur which is caused by the influence of the average monthly temperature A time will be stored in the register which equals the number of milliseconds since 01 01 1970 15 values will be stored corresponding to 14 monthly intervals The correction will be applied ...

Page 22: ...that is running behind and a negative value is used to correct a clock that is running ahead The input of the correction Value is in milliseconds The correction is determined over a period of one month Note that this correction is only a correction for the standard deviation of the clock and ignores e g temperature drift The monthly correction determined is based on the difference between the inte...

Page 23: ...w the start date of battery 1 Group 1 and the start date of battery 2 Group 2 will be displayed At Alarm start the date at which the status is changed into Replacement after X months will be displayed Where X is defined in the config file usually this is 6 months In case of a new device a date in the far future will be displayed for battery 2 to indicate that this battery is not yet in operation A...

Page 24: ... type must be put back in its proper position This file type is XML and can be modified by using a simple editor WordPad notepad The extension of the config file is cfg 3 The config file can be written into the modem by using the button 3 Write configuration into the modem 4 Created or read configurations can be saved and used again later The same applies for the modem settings such as provider na...

Page 25: ... be read directly in MS Excel An example filename 0000471120120427072212 csv In column A the Day Date Time and Year are displayed In column B the status of the measurement for the corresponding hour is displayed Here is an encoder and an active alarm displayed In column C a location is reserved for a gas temperature measurement In column D the actual index value of the gas meter is displayed in th...

Page 26: ...pplication If the gACC 499E U is in sleep mode this must be awakened first In order to do this DIP switch 1 must be turned from ON to OFF DIP switch 3 must be turned ON in order to follow the status by using the LED s Before turning DIP switch 1 back to ON approx 1 minute must be waited When all LEDs are on DIP switch 4 must be turned ON After a short while the GSM and CONNECTED LED will turn off ...

Page 27: ...e gACC is restarted and all internal data to be cached immediately 3 With the button 3 Trigger an update can be triggered locally by using a config cable This is only possible using GPRS because the update uses TCP IP communication Pay attention to the hidden features for Trigger update and Reset 3 2 SMS update In order to send a SMS the correct COM port must be selected to which the modem is conn...

Page 28: ...ically and the Firmware will be sent in blocks of 512 bytes to the corresponding gACC 499E U The files are compressed java files with the extensions jar and jad The Firmware will be sent to the gACC 499E U entirely and will program the device by itself While sending the files a checksum is used to check whether the files are sent without errors 3 4 Local update With a so called debug cable it is p...

Page 29: ...gACC 499E U Communication unit gACC 499E_U_Manual_EN doc Reset Ctrl Reset To erase the archive Ctrl and Reset must be clicked simultaneously and in the following window to be confirmed with Yes The entire content of the archive is deleted ...

Page 30: ...t is also possible to connect this sensor at a later time The temperature sensor is from the perspective of ATEX IEC 60079 11 par 5 7 as simple apparatus declared The temperature sensor may not be placed in the gas stream but must be placed in a so called thermowell 4 2 5 Pulses The gACC 499E U is equipped with a pulse input to which a potential free contact of the gas meter can be connected The p...

Page 31: ...ner Barriere Ex 499 UW is used 5 2 3 Connections gACC 499E U Terminal EX 499 UW Function 1 GND Signal line 2 Encoder signal Signal line 3 GND Signal line gAVC 1200 XP2 terminal B 4 UniWire Signal line gAVC 1200 XP2 terminal A 9 GND Signal line 10 Pulse signal Signal line In order to use the pulse input channel 4 of the Zener Barrier must be assembled 5 2 4 The dividing wall The dividing wall can b...

Page 32: ...GA 02 035 EN 30 05 17 Page 32 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc 5 2 6 Scheme Zener Barrier 5 2 7 Type plate gACC 499E U ...

Page 33: ...d in case of saturation Whether and how often the pack needs to be changed is highly dependent on local conditions and also the skill with which the appliance is installed It is very essential that the cable entry glands are sufficiently tightened after installation and also the cover should be placed precisely on the housing in accordance with a clean seal in the cover The unit should never be op...

Page 34: ...RTC with a max deviation of 5ppm per year In consultation with the customer the choice can be made that the devices are delivered with the clock set to the correct time If the clock is not set to the correct time this can be done in several ways Setting time with the configuration program and a config cable By clicking Set time the time of the PC will be written into the gACC 499E U ...

Page 35: ... of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc 6 2 Setting time remotely Setting the time with the configuration software and a modem Select the correct COM port of the modem and enter the init string at modem init ...

Page 36: ...er of the gas meter or gAVC 1200 U1200_12345678 CR LF or FLO5UF12345678 CR LF confirm with Baud rate ACK 051 CR LF SOH P0 STX 1234567 ETX 1234567 fixed dummy password SOH P1 STX xxxxxxxx ETX V xxxxxxxx internal password ACK SOH W5 STX 0 9 1 0150338 xxxxxxxx ETX P xxxxxxxx internal password ACK SOH W5 STX 0 9 2 0090303 xxxxxxxx ETX V xxxxxxxx internal password ACK SOH B0 ETX q ...

Page 37: ...t switch 2 to ON 8 Wait until all 4 LEDs are on plus about 3 minutes 9 Now the data collection system can run a test whereby billing data and a clock synchronization can carried out load profile data will not yet be available at this moment 7 2 gAVC 1200 exchange Before the gAVC 1200 is disconnected 1 Remove the cover of the gACC 499E U 2 Set switch 2 to ON 3 Set switch 3 to ON 4 Wait until all 4 ...

Page 38: ...in for the period of fully charged batteries Note that the lifespan of the batteries is greatly affected by the signal reception strength For areas with poor network coverage a third battery pack can be placed This third pack will be connected to the Bat3 connector In the config file an adjustment needs to be made the parameter dualmainbatt n has to be changed in dualmainbatt y 7 4 Cache Reset In ...

Page 39: ...LEDs go out and then immediately remove the config cable 8 Wait unitl the READY GSM and CONNECTED LED are on again 9 After a few minutes the device will turn off again This is dependent of the call windows If there is an active call window open this may take longer 10 Remember to switch DIP switch 3 to OFF ...

Page 40: ...GA 02 035 EN 30 05 17 Page 40 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc 8 0 EC Type Examination Certificate ...

Page 41: ...GA 02 035 EN 30 05 17 Page 41 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...

Page 42: ...GA 02 035 EN 30 05 17 Page 42 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...

Page 43: ...GA 02 035 EN 30 05 17 Page 43 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...

Page 44: ...GA 02 035 EN 30 05 17 Page 44 of 46 gACC 499E U Communication unit gACC 499E_U_Manual_EN doc ...

Page 45: ...We Flonidan A S Islandsvej 29 DK 8700 Horsens hereby confirm that the product EX 499 UW has been manufactured identically to the sample tested in the above EC Type examination certificate and thus conforms to the standards EN 60079 0 2012 EN 60079 11 2012 EN 60079 25 2007 Horsens den 03 12 2013 Bo Friis Hansen Flonidan A S ...

Page 46: ...____ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ________________________________________________________________________ ______________________________...

Reviews: