Instructions for DKC500ACL/DKC800ACL
www.gatexpertstore.com
20
Photocell
Transmitters
2
芯线
Before Installing Photocells
Loosen 8 and 9 ports on J5 Terminal
with a screwdriver. Make sure the power
is disconnected before doing so.
Remove the wire jumper
Between ports 8 & 9 on J5
Terminal.
Connecting Infrared Photocells
The below steps must be completed by licensed electrician.
Highly recommend the use of infrared photocells as an additional safety feature.
While closing, if the ray of the Infrared Photocell is blocked, the gate will stop and reverse
immediately, to protect user and property security. To install photocells, connect wiring as
per Figure 19. You must remove the wire jumper between terminal 8 and terminal 9 on J5
(ref to Figure 20).
The distance between photocell receiver and photocell transmitter should not be less than 2
meters; otherwise, the induction effect of photocell may be affected.
Figure 19
Figure 20
Photocell
Receiver
3
芯线
2 core
cable
3 core
cable