Instructions for DKC500ACL/DKC800ACL
www.gatexpertstore.com
18
Terminal Instructions
All changes to these settings below must be completed by licensed electrician.
Note: If require to change the moving direction, the wires of 11 and 13 on J5 Terminal
have to be swapped with each other.
J2 Terminal (as per Figure 16):
Terminal 6:
External Push Button Pedestrian Switch
Terminal 5:
External Open/Stop/Close/Stop Loop Control Push
Button (Repeated Open/Stop/Close)
Terminal 4:
Common Terminal for All External Control Push
Button
Terminal 3:
External Stop Push Button Switch.
Terminal 2:
External Open Push Button Switch.
Terminal 1:
External Close Push Button Switch.
J5 Terminal:
Limit Switch and Accessories
Additional accessories sold separately
Terminal 13:
Open Limit Switch
Terminal 12:
Limit Switch Common Terminal
Terminal 11:
Close Limit Switch
Terminal 10:
Loop Detector Connector (Pre-wired by Factory)
Terminal 9:
Ground/Earth (GND)
Terminal 8:
Photocell input (N.C.).
If no photocell is fitted, use
a jumper between terminals 8 & 9.
Terminal 7:
Power supply for accessories (+15V)