Instructions for DKC500ACL/DKC800ACL
www.gatexpertstore.com
24
Terminal Instructions
All changes to these settings must be completed by a licensed electrician
Note: If require to change the moving direction, the CLLM and OPLM on X5 Terminal
have to be swapped with each other.
X5 Terminal:
Limit Switch and Photocell Switch.
Additional accessories sold separately
24VDC: Positive Power Supply for Acces24VDC.
GND: Negative Power Supply for Accessories -GND.
LR:
Photocell Input (N.C.).
If no photocell, connect LR and GND by a jumper.
CLLM: Close Limit Switch.
COM: Limit Switch Common Terminal.
OPLM: Open Limit Switch.
X4 Terminal:
External Push Button.
COM: Common Terminal for External Push Button.
STP:
External Stop Push Button Switch.
CLS:
External Close Push Button Switch.
OPN:
External Open Push Button Switch.