The information given below is for guidance only and it cannot be assumed that it 
complies with national and local regulations. 

 
Consider  the  total  ventilation  requirements  for  simultaneous  operating  with  other  heating 
appliances.    For  this  appliance  only,  the  room  or  space  containing  this  appliance  needs  a 
permanent, unobstructed air opening of at least 825 mm

2

 to satisfy UK Building Regulations.   

Limited air for combustion may result in poor performance, smoking and other side effects of 
poor combustion. 
 
Every effort must be made to ensure that air vents installed for this appliance are kept clear of 
debris and in full working order at all times.    Preferably the grilles should be positioned as 
close to the appliance as practicable where air supply to the appliance will be unimpeded.   
 
There must not be an extractor fan fitted in the same room as the stove as this can cause the 
stove to emit fumes into the room 
 
The stove air input pipe diameter is ¢50 mm, venting pipe diameter is ¢80 mm. The total 
length of pipes is not longer than 3m. Indoor venting pipe joint should be sealed by silicone 
sealant  to  prevent  exhaust  leaking into  the room.  Venting  pipe and  termination should be 
waterproof and avoid being blocked. Or, the stove cannot work properly. 
 
When the installation is limited by space or the owner’s special requirements and the pipes’ 
length should be longer than 3m and need elbows, the diameters of the air input pipe and 
venting pipe must be increased properly for smooth convection. If not, it will influence the 
burning and the stove cannot work properly. The owner should connect with the local seller for 
the right installation.   
 
When the pellet stove is working normally, the temperature on venting pipe surface can reach 
200˚C, so combustible materials, clothes and furniture should be away from the venting pipe. 
To prevent burns, do not touch the heating surface! 
 
When installing the appliance, suitable access should be provided for cleaning the appliance, 
flue gas connector and chimney flue. 
 

Summary of Contents for HP24

Page 1: ...estrictions and installation inspection requirements in your area PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COU...

Page 2: ...6 9 Troubleshooting 17 10 Warranty 18 11 Figure Electricity control 19 Technical Specification Stove Mass 98 kg Nominal output Maximum setting Total Efficiency 92 3 Nominal Heat Output 9 4 kW Mean CO...

Page 3: ...ed pellet type P F I PELLET STANDARDS Fines fine particles 1 maximum through a 3 mm 1 8 screen Bulk Density 650 kg m3 minimum Size 6 mm to 8 mm diameter 12mm to 35 mm long Ash Content 1 maximum Premiu...

Page 4: ...s The stove s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure A chimney draught of 12 Pa can be regarded as typical when operating at maximum ou...

Page 5: ...sposed ashes should be placed in a metal container The closed container of ashes should be on a non combustible floor on the ground well away from all combustible materials pending final disposal If t...

Page 6: ...T DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FRESH AIR Outside Fresh Air connection is optional It must be connected to all units installed in Mobile and Air Tight Homes R200...

Page 7: ...ature is still above 120 F 52 C Product performance The pellet stove has an advanced designed and has individual fresh air input and venting system Negative pressure burning technology causes high eff...

Page 8: ...clearance between the walls or to the top should be no less than the size in the figure Min installation clearance mm 2 Electrical The unit must be grounded earthed The grounded electrical cord should...

Page 9: ...fumes into the room The stove air input pipe diameter is 50 mm venting pipe diameter is 80 mm The total length of pipes is not longer than 3m Indoor venting pipe joint should be sealed by silicone sea...

Page 10: ...Page 10 19...

Page 11: ...l Temp and Weekly 5 TIMER BUTTON Order the start time or shutdown time of the unit Press Timer then set the period of time you needed attention the maximum is 7 hours Minimum is 1 hour After setting 5...

Page 12: ...WEEKLY PROGRAMMER Temperature Units Blower Voltage and Exhaust Voltage Restore default setting and use Diagnostic platform are also access 8 CONCEL BUTTON 9 UP AND DOWN BUTTON Three status s descript...

Page 13: ...TEMPERATURE 5 MAIN MODE HEATING POWER LEVEL IGNITOR COMBUSTION BLOWER blower AUGER CONVECTION BLOWER VACUUM SWITCH LIMIT SWITCH ON OFF STATE ADDITIONAL CONTROL MODE MAIN MODE DATE and TIME WORK STAGE...

Page 14: ...The stove will power off and the fire will be put out when the auger motor stops b The stove will power off and the fire will be put out when the convection blower stops c Auger motor stops feeding w...

Page 15: ...round the stove when it is operating 3 When installing this unit on a combustible floor for example linoleum hardwood flooring a non combustible hearth pad 15mm thickness with sufficient load bearing...

Page 16: ...way any fly ash that may have collected on the heat exchanger tubes 5 Put the ash in the ash drawer out TIMELY 6 When the appliance is not to be used for a long time it should be cleaned completely Es...

Page 17: ...ht the high temperature switches connection Change the high temperature switch D Three lights aren t bright No 220V power Pellet feeder is power off The wires of start and clock unit loose or break Ch...

Page 18: ...own the blower Clean the heat exchange tubes 8 Ash and smoke fly out Leak between the connection of convection motor and venting pipe The clean method is wrong Use silicon rubber to seal Clean the dus...