PELLET

 

FEED

 

RATES:

 

Due to different fuel densities and sizes, pellet feed rates may vary.   

This may require an adjustment to the slider damper setting or to the auger feed trim setting 
on  low.    These  modifications  should  be  carried  out  during  commissioning  by  a  qualified 
installer. 

 

Since the stove supplier has no control over the quality of pellets that you use, we assume no 
liability for your choice in wood pellets. 

 

Store

 

pellets

 

at

 

least

 

36”

 

(1

 

m)

 

away

 

from

 

the

 

pellet

 

stove. 

 
I

MPORTANT

 

S

AFETY

 

D

ATA

:

 

 

Please

 

read

 

this

 

Owner’s

 

Manual

 

before

 

installing

 

or

 

operating

 

your

 

Pellet Stove.

 

Failure

 

to

 

follow

 

these

 

instructions

 

may

 

result

 

in

 

property

 

damage,

 

bodily

 

injury or

 

even

 

death.

   

Contact  your  local  building  or  fire  official  to  obtain  a  permit  and  any 

information on installation restrictions and inspection requirements for your area. 

It is imperative that all national and local regulations and European Standards are 
complied with when installing the appliance. 

To prevent the possibility of a fire, ensure that the appliance is properly installed by adhering 
to the installation instructions. The dealer will be happy to assist you in obtaining information 
with regard to your local building codes and installation restrictions. 
Be sure to maintain the structural integrity of the home when passing a vent through walls, 
ceilings, or roofs. 
The stove’s exhaust system works with negative combustion chamber pressure and a slightly 
positive  chimney  pressure.  A  chimney  draught  of  12  Pa  can  be  regarded  as  typical  when 
operating at maximum output.    It is very important to ensure that the exhaust system be 
sealed and airtight. The ash pan and viewing door must be locked securely for proper and safe 
operation of the pellet stove. 
In  a  small  number  of  installations,  occasional  local  weather  conditions  (e.g.  wind  from  a 
particular direction) may cause downdraught in the flue and cause the stove to emit fumes.   
In these circumstances, the stove should not be used.    A professional flue installer will be 
able to advise on solutions to this problem 
Do  not  burn  with  insufficient  combustion  air.  A  periodic  check  is  recommended  to  ensure 
proper  combustion  air  is  admitted  to  the  combustion  chamber.    Setting  the  proper 
combustion air is achieved by adjusting the slider damper located on the left side of the stove. 

When  installing  the  stove  in  a  mobile  home,  it  must  be  electrically  grounded  to  the  steel 
chassis of the home and bolted to the floor.    Make sure that the structural integrity of the 
home is maintained and all construction meets local building codes. 

Minor soot or creosote may accumulate when the stove is operated under incorrect conditions 
such as an extremely rich burn (black tipped, lazy orange flames). 
If you  have  any  questions with regard  to  your stove  or the  above-mentioned  information, 
please feel free to contact your local dealer for further clarification and comments. 

Summary of Contents for HP24

Page 1: ...estrictions and installation inspection requirements in your area PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COU...

Page 2: ...6 9 Troubleshooting 17 10 Warranty 18 11 Figure Electricity control 19 Technical Specification Stove Mass 98 kg Nominal output Maximum setting Total Efficiency 92 3 Nominal Heat Output 9 4 kW Mean CO...

Page 3: ...ed pellet type P F I PELLET STANDARDS Fines fine particles 1 maximum through a 3 mm 1 8 screen Bulk Density 650 kg m3 minimum Size 6 mm to 8 mm diameter 12mm to 35 mm long Ash Content 1 maximum Premiu...

Page 4: ...s The stove s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure A chimney draught of 12 Pa can be regarded as typical when operating at maximum ou...

Page 5: ...sposed ashes should be placed in a metal container The closed container of ashes should be on a non combustible floor on the ground well away from all combustible materials pending final disposal If t...

Page 6: ...T DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FRESH AIR Outside Fresh Air connection is optional It must be connected to all units installed in Mobile and Air Tight Homes R200...

Page 7: ...ature is still above 120 F 52 C Product performance The pellet stove has an advanced designed and has individual fresh air input and venting system Negative pressure burning technology causes high eff...

Page 8: ...clearance between the walls or to the top should be no less than the size in the figure Min installation clearance mm 2 Electrical The unit must be grounded earthed The grounded electrical cord should...

Page 9: ...fumes into the room The stove air input pipe diameter is 50 mm venting pipe diameter is 80 mm The total length of pipes is not longer than 3m Indoor venting pipe joint should be sealed by silicone sea...

Page 10: ...Page 10 19...

Page 11: ...l Temp and Weekly 5 TIMER BUTTON Order the start time or shutdown time of the unit Press Timer then set the period of time you needed attention the maximum is 7 hours Minimum is 1 hour After setting 5...

Page 12: ...WEEKLY PROGRAMMER Temperature Units Blower Voltage and Exhaust Voltage Restore default setting and use Diagnostic platform are also access 8 CONCEL BUTTON 9 UP AND DOWN BUTTON Three status s descript...

Page 13: ...TEMPERATURE 5 MAIN MODE HEATING POWER LEVEL IGNITOR COMBUSTION BLOWER blower AUGER CONVECTION BLOWER VACUUM SWITCH LIMIT SWITCH ON OFF STATE ADDITIONAL CONTROL MODE MAIN MODE DATE and TIME WORK STAGE...

Page 14: ...The stove will power off and the fire will be put out when the auger motor stops b The stove will power off and the fire will be put out when the convection blower stops c Auger motor stops feeding w...

Page 15: ...round the stove when it is operating 3 When installing this unit on a combustible floor for example linoleum hardwood flooring a non combustible hearth pad 15mm thickness with sufficient load bearing...

Page 16: ...way any fly ash that may have collected on the heat exchanger tubes 5 Put the ash in the ash drawer out TIMELY 6 When the appliance is not to be used for a long time it should be cleaned completely Es...

Page 17: ...ht the high temperature switches connection Change the high temperature switch D Three lights aren t bright No 220V power Pellet feeder is power off The wires of start and clock unit loose or break Ch...

Page 18: ...own the blower Clean the heat exchange tubes 8 Ash and smoke fly out Leak between the connection of convection motor and venting pipe The clean method is wrong Use silicon rubber to seal Clean the dus...

Page 19: ...Page 19 19...