FLAMMABLE

 

LIQUIDS:

   

Never

 

use

 

Flammable Liquid such as

 gasoline, gasoline-type   

lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to start or “freshen up” a fire in 
the heater.    Keep all such liquids well away from the heater while it is in use. 

 

SMOKE

 

DETECTOR:

   

Smoke detectors should be installed and maintained in the structure 

when installing and operating a pellet burning appliance. 

 

OPERATION:

 

The ash pan and door must be closed securely for proper and safe operation of 

the  pellet  stove.    Also  ensure  all  gaskets  on  the  door  are  checked  and  replaced  when 
necessary. 

 

KEEP

 

ASH

 

PAN

 

FREE

 

OF

 

RAW

 

FUEL.

 

To avoid a fire in the ash pan, DO NOT PLACE UNBURNED OR NEW PELLET FUEL IN ASH PAN.     

 

INSTALLATION:

 

Be sure to maintain the structural integrity of your home when passing a 

vent  through walls, ceilings,  or roofs.  It  is recommended that  the  unit  be secured  into  its 
position in order to avoid any displacement. 
DO NOT INSTALL A FLUE DAMPER IN THE EXHAUST VENTING SYSTEM OF THIS UNIT.   
DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE. 

 

FRESH

 

AIR:

 

Outside  Fresh  Air  connection  is  optional.    It  must  be  connected  to  all  units 

installed in Mobile and “Air Tight Homes” (R2000) or where required by local codes.    Consider 
the total ventilation requirements for simultaneous operating with other heating appliances.   
For  this  appliance  only,  the  room  or  space  containing  this  appliance  needs  a  permanent, 
unobstructed air opening of at least 825 mm

2

 to satisfy UK Building Regulations.    Limited air 

for  combustion  may  result  in  poor  performance,  smoking  and  other  side  effects  of  poor 
combustion. 
 
All air inlet grilles should be positioned so that they are not liable to blockage. 

 

If you have any questions with regards to your stove or the above-mentioned information, 
please feel free to contact your local dealer for further clarification and comments. 

 

SINCE  THE  STOVE  SUPPLIER  HAS  NO  CONTROL  OVER  THE  INSTALLATION  OF 
YOUR STOVE, THE STOVE SUPPLIER GRANTS NO WARRANTY IMPLIED OR STATED 
FOR THE

 

INSTALLATION

 

OR

 

MAINTENANCE

 

OF

 

YOUR

 

STOVE.

   

THEREFORE,

 

THE

 

STOVE  SUPPLIER

 

ASSUMES

 

NO

 

RESPONSIBILITY

 

FOR

 

ANY

 

CONSEQUENTIAL

 

DAMAGE(S).

 

SAVE

 

THIS

 

INSTRUCTION

 

MANUAL

 

FOR

 

FUTURE

 

REFERENCE! 

Summary of Contents for HP24

Page 1: ...estrictions and installation inspection requirements in your area PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COU...

Page 2: ...6 9 Troubleshooting 17 10 Warranty 18 11 Figure Electricity control 19 Technical Specification Stove Mass 98 kg Nominal output Maximum setting Total Efficiency 92 3 Nominal Heat Output 9 4 kW Mean CO...

Page 3: ...ed pellet type P F I PELLET STANDARDS Fines fine particles 1 maximum through a 3 mm 1 8 screen Bulk Density 650 kg m3 minimum Size 6 mm to 8 mm diameter 12mm to 35 mm long Ash Content 1 maximum Premiu...

Page 4: ...s The stove s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure A chimney draught of 12 Pa can be regarded as typical when operating at maximum ou...

Page 5: ...sposed ashes should be placed in a metal container The closed container of ashes should be on a non combustible floor on the ground well away from all combustible materials pending final disposal If t...

Page 6: ...T DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FRESH AIR Outside Fresh Air connection is optional It must be connected to all units installed in Mobile and Air Tight Homes R200...

Page 7: ...ature is still above 120 F 52 C Product performance The pellet stove has an advanced designed and has individual fresh air input and venting system Negative pressure burning technology causes high eff...

Page 8: ...clearance between the walls or to the top should be no less than the size in the figure Min installation clearance mm 2 Electrical The unit must be grounded earthed The grounded electrical cord should...

Page 9: ...fumes into the room The stove air input pipe diameter is 50 mm venting pipe diameter is 80 mm The total length of pipes is not longer than 3m Indoor venting pipe joint should be sealed by silicone sea...

Page 10: ...Page 10 19...

Page 11: ...l Temp and Weekly 5 TIMER BUTTON Order the start time or shutdown time of the unit Press Timer then set the period of time you needed attention the maximum is 7 hours Minimum is 1 hour After setting 5...

Page 12: ...WEEKLY PROGRAMMER Temperature Units Blower Voltage and Exhaust Voltage Restore default setting and use Diagnostic platform are also access 8 CONCEL BUTTON 9 UP AND DOWN BUTTON Three status s descript...

Page 13: ...TEMPERATURE 5 MAIN MODE HEATING POWER LEVEL IGNITOR COMBUSTION BLOWER blower AUGER CONVECTION BLOWER VACUUM SWITCH LIMIT SWITCH ON OFF STATE ADDITIONAL CONTROL MODE MAIN MODE DATE and TIME WORK STAGE...

Page 14: ...The stove will power off and the fire will be put out when the auger motor stops b The stove will power off and the fire will be put out when the convection blower stops c Auger motor stops feeding w...

Page 15: ...round the stove when it is operating 3 When installing this unit on a combustible floor for example linoleum hardwood flooring a non combustible hearth pad 15mm thickness with sufficient load bearing...

Page 16: ...way any fly ash that may have collected on the heat exchanger tubes 5 Put the ash in the ash drawer out TIMELY 6 When the appliance is not to be used for a long time it should be cleaned completely Es...

Page 17: ...ht the high temperature switches connection Change the high temperature switch D Three lights aren t bright No 220V power Pellet feeder is power off The wires of start and clock unit loose or break Ch...

Page 18: ...own the blower Clean the heat exchange tubes 8 Ash and smoke fly out Leak between the connection of convection motor and venting pipe The clean method is wrong Use silicon rubber to seal Clean the dus...

Page 19: ...Page 19 19...