![Gaswinkel HP24 Owner'S Manual Download Page 15](http://html1.mh-extra.com/html/gaswinkel/hp24/hp24_owners-manual_3713770015.webp)
Page 15 / 19
standards. Ask your dealer for a recommended pellet type.
2. Please keep the door closed and sealed at all times during burning. This is for good effect
and prevents hot ash flying out. As soon as the door is opened the auger stops feeding
pellets and the appliance will go into shut-down mode.
3. The good burning features are a-bright yellow flame of the pellets burning with a little
jumping in the gratebar (combustion retort). Pellets should not pile up and there should be
no smoke. If the combustion pattern changes to a little dark glow with a lazy flame and smoke
appearing from the venting terminal, the convection blower to increase the air input needs
speeding up. This should only be carried out by a suitably qualified engineer.
4. For reducing the heat output, it is better to reduce the pellet feed. At the same time the
speeds of convection blower and exhaust blower should be turned down until the best effect is
attained. This should only be carried out by a suitably qualified engineer.
2.
Venting pipe and air input pipe should keep unblocked.
Safety instructions
1.
The power jack must be grounded (earthed).
2.
No combustion or explosive materials around the stove when it is operating.
3.
When installing this unit on a combustible floor (for example linoleum, hardwood flooring)
a non-combustible hearth pad (15mm thickness), with sufficient load-bearing capacity
must be under the unit.
4.
Do not open the stove door when the stove is operating.
5.
Do not touch the surface when the stove is operating. The high temperature of the stove
glass door and venting pipe will cause burns.
6.
Use only the auto-ignition device to light the appliance. For safety, do not use gasoline or
other combustion or explosive materials to ignite the appliance
7.
After a prolonged shut down period ensure that all passageways for supply air and
exhaust gases are free from blockage.
8.
In the event of a chimney fire :-
Raise the alarm to let others in the house know.
Call the Fire Brigade.
Reduce the appliance-burning rate by closing all air controls.
Move furniture and rugs away from the fireplace and remove any nearby ornaments.
Place a fireguard or spark guard in front of the stove.
Feel the chimney breast for signs of excessive heat. If the wall is becoming hot,
move furniture away.
Ensure that the Fire Brigade can gain access to your roof space in order to check for
signs of fire spread.
Maintenance
NO
unauthorised modification of this appliance should be carried out.
This appliance requires regular maintenance by a competent engineer.