                                                                                                Page 15    /    19 

standards. Ask your dealer for a recommended pellet type. 
2. Please keep the door closed and sealed at all times during burning.    This is for good effect 
and  prevents  hot  ash  flying out.    As soon  as the  door  is opened  the  auger  stops  feeding 
pellets and the appliance will go into shut-down mode.     
3. The  good  burning  features  are  a-bright  yellow flame  of  the  pellets  burning  with a  little 
jumping in the gratebar (combustion retort).    Pellets should not pile up and there should be 
no smoke. If the combustion pattern changes to a little dark glow with a lazy flame and smoke 
appearing from the venting terminal, the convection blower to increase the air input needs 
speeding up.    This should only be carried out by a suitably qualified engineer. 
4. For reducing the heat output, it is better to reduce the pellet feed.    At the same time the 
speeds of convection blower and exhaust blower should be turned down until the best effect is 
attained. This should only be carried out by a suitably qualified engineer. 
2.

 

Venting pipe and air input pipe should keep unblocked. 

Safety instructions 

1.

 

The power jack must be grounded (earthed). 

2.

 

No combustion or explosive materials around the stove when it is operating. 

3.

 

When installing this unit on a combustible floor (for example linoleum, hardwood flooring) 
a  non-combustible  hearth  pad  (15mm thickness),  with sufficient  load-bearing  capacity 
must be under the unit. 

4.

 

Do not open the stove door when the stove is operating. 

5.

 

Do not touch the surface when the stove is operating. The high temperature of the stove 
glass door and venting pipe will cause burns. 

6.

 

Use only the auto-ignition device to light the appliance. For safety, do not use gasoline or 
other combustion or explosive materials to ignite the appliance 

7.

 

After  a  prolonged  shut  down  period  ensure  that  all  passageways  for  supply  air  and 
exhaust gases are free from blockage. 

8.

 

In the event of a chimney fire :- 

 

Raise the alarm to let others in the house know. 

 

Call the Fire Brigade. 

 

Reduce the appliance-burning rate by closing all air controls. 

 

Move furniture and rugs away from the fireplace and remove any nearby ornaments. 

 

Place a fireguard or spark guard in front of the stove. 

 

Feel the chimney breast for signs of excessive heat.    If the wall is becoming hot, 

move furniture away. 

 

Ensure that the Fire Brigade can gain access to your roof space in order to check for 

signs of fire spread. 

 

Maintenance   

 
NO

 unauthorised modification of this appliance should be carried out. 

 
This appliance requires regular maintenance by a competent engineer. 

Summary of Contents for HP24

Page 1: ...estrictions and installation inspection requirements in your area PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COU...

Page 2: ...6 9 Troubleshooting 17 10 Warranty 18 11 Figure Electricity control 19 Technical Specification Stove Mass 98 kg Nominal output Maximum setting Total Efficiency 92 3 Nominal Heat Output 9 4 kW Mean CO...

Page 3: ...ed pellet type P F I PELLET STANDARDS Fines fine particles 1 maximum through a 3 mm 1 8 screen Bulk Density 650 kg m3 minimum Size 6 mm to 8 mm diameter 12mm to 35 mm long Ash Content 1 maximum Premiu...

Page 4: ...s The stove s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure A chimney draught of 12 Pa can be regarded as typical when operating at maximum ou...

Page 5: ...sposed ashes should be placed in a metal container The closed container of ashes should be on a non combustible floor on the ground well away from all combustible materials pending final disposal If t...

Page 6: ...T DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FRESH AIR Outside Fresh Air connection is optional It must be connected to all units installed in Mobile and Air Tight Homes R200...

Page 7: ...ature is still above 120 F 52 C Product performance The pellet stove has an advanced designed and has individual fresh air input and venting system Negative pressure burning technology causes high eff...

Page 8: ...clearance between the walls or to the top should be no less than the size in the figure Min installation clearance mm 2 Electrical The unit must be grounded earthed The grounded electrical cord should...

Page 9: ...fumes into the room The stove air input pipe diameter is 50 mm venting pipe diameter is 80 mm The total length of pipes is not longer than 3m Indoor venting pipe joint should be sealed by silicone sea...

Page 10: ...Page 10 19...

Page 11: ...l Temp and Weekly 5 TIMER BUTTON Order the start time or shutdown time of the unit Press Timer then set the period of time you needed attention the maximum is 7 hours Minimum is 1 hour After setting 5...

Page 12: ...WEEKLY PROGRAMMER Temperature Units Blower Voltage and Exhaust Voltage Restore default setting and use Diagnostic platform are also access 8 CONCEL BUTTON 9 UP AND DOWN BUTTON Three status s descript...

Page 13: ...TEMPERATURE 5 MAIN MODE HEATING POWER LEVEL IGNITOR COMBUSTION BLOWER blower AUGER CONVECTION BLOWER VACUUM SWITCH LIMIT SWITCH ON OFF STATE ADDITIONAL CONTROL MODE MAIN MODE DATE and TIME WORK STAGE...

Page 14: ...The stove will power off and the fire will be put out when the auger motor stops b The stove will power off and the fire will be put out when the convection blower stops c Auger motor stops feeding w...

Page 15: ...round the stove when it is operating 3 When installing this unit on a combustible floor for example linoleum hardwood flooring a non combustible hearth pad 15mm thickness with sufficient load bearing...

Page 16: ...way any fly ash that may have collected on the heat exchanger tubes 5 Put the ash in the ash drawer out TIMELY 6 When the appliance is not to be used for a long time it should be cleaned completely Es...

Page 17: ...ht the high temperature switches connection Change the high temperature switch D Three lights aren t bright No 220V power Pellet feeder is power off The wires of start and clock unit loose or break Ch...

Page 18: ...own the blower Clean the heat exchange tubes 8 Ash and smoke fly out Leak between the connection of convection motor and venting pipe The clean method is wrong Use silicon rubber to seal Clean the dus...

Page 19: ...Page 19 19...