Page 14 / 19
6. ADDITIONAL CONTROL MODE
7. ON/OFF STATE
8. COMPONENT STATE DISPLAY AREA:
As showed in the photo, there are six components indicator in the component
state display area, including IGNITOR, COMBUSTION BLOWER, AUGER,
CONVECTION BLOWER, VACUUM SWITCH and LIMIT SWITCH. Once
the component starts running or its contact close, the corresponding indicator
appears.
9. WORK STAGE:
Ignition
,
heating
,
fire off
10. HEATING POWER LEVEL:
From 1 to 5, the heating output goes up.
Safety program
a.
The stove will power off and the fire will be put out when the auger motor stops.
b.
The stove will power off and the fire will be put out when the convection blower stops.
c.
Auger motor stops feeding when thermodisc T3≥93˚C. When the T3<93˚C, the auger
motor feeds again, the stove will keep working.
Caution
1. It is important to select and use only pellets that are dry and free of dirt or any impurities
such as high salt content. Dirty fuel will adversely affect the operation and performance of the
unit and will void the warranty. The Pellet Fuel Industries (P.F.I.) has established standards for
wood pellet manufacturers. We recommend the use of pellets that meet or exceed these
Summary of Contents for HP24