background image

                                                                                                Page 7    /    19 

Caution: Keep the fire box clean, before you start the stove. 

 

 

A

UTOMATIC

   

S

AFETY

   

F

EATURES

:

 

 
Your pellet Stove has the following safety features: 

A.  The    stove    will    shut    off    when    the    fire    goes    out    and    the    exhaust   

temperature    drops    below    120°F(52°C). 

B. The stove has a high temperature safety switch. If the temperature on the hopper reaches 
200°F 
(93°C),  the  auger  will  automatically  stop  and  the  stove  will  shut  down  when  the  exhaust 
temperature cools.    If this happens, call your local dealer to reset the 200°F (93°C) high limit 
switch. 

ALSO

 

FIND

 

THE

 

REASONS

 

WHY

 

THE

 

UNIT

 

OVERHEATED.

 

C. If the power goes out, the unit will stop running.    When the power comes back on, the stove 

will not restart unless the exhaust temperature is still above 120°F (52 °C). 

 

Product performance   

The  pellet  stove  has  an  advanced  designed  and  has  individual  fresh  air  input  and  venting 
system.  Negative  pressure  burning  technology  causes  high  efficiency  and  little  ash  outlet 
during burning. It will be shut off automatically by wrong burning or if out of fuel. Large heat 
output, quick heating and low fuel cost are its advantages.       
 

1.

 

Main performance   

Model 

    HP24 

Rating input                                  BTU/h 

30000BTU/H(9.4KW/HOUR) 

Rating fuel consumption            kg/h 

1.6 +_5% 

Heating area                                m

²

 

~120 

Rating voltage                              V 

230 

Rating frequency                          Hz 

50 

Maximum power requirement    W 

375 

Hopper                                            kg 

20 

Venting pipe diameter                mm 

80 

Air input pipe diameter              mm 

50 

Unit size (wide* depth*high)    mm 

650*600*1000 

 

2.

 

  Wood pellet 

This stove uses wood pellet fuel. It is small column pellet with cleaning surface. The diameter 
is ¢6-8mm, the length is no more than 35mm, and its humidity is no more than 10%. Ash is no 
more than 1%. 
 

Summary of Contents for HP24

Page 1: ...estrictions and installation inspection requirements in your area PLEASE READ THIS ENTIRE MANUAL BEFORE INSTALLATION AND USE OF THIS PELLET BURNING ROOM HEATER FAILURE TO FOLLOW THESE INSTRUCTIONS COU...

Page 2: ...6 9 Troubleshooting 17 10 Warranty 18 11 Figure Electricity control 19 Technical Specification Stove Mass 98 kg Nominal output Maximum setting Total Efficiency 92 3 Nominal Heat Output 9 4 kW Mean CO...

Page 3: ...ed pellet type P F I PELLET STANDARDS Fines fine particles 1 maximum through a 3 mm 1 8 screen Bulk Density 650 kg m3 minimum Size 6 mm to 8 mm diameter 12mm to 35 mm long Ash Content 1 maximum Premiu...

Page 4: ...s The stove s exhaust system works with negative combustion chamber pressure and a slightly positive chimney pressure A chimney draught of 12 Pa can be regarded as typical when operating at maximum ou...

Page 5: ...sposed ashes should be placed in a metal container The closed container of ashes should be on a non combustible floor on the ground well away from all combustible materials pending final disposal If t...

Page 6: ...T DO NOT CONNECT THIS UNIT TO A CHIMNEY FLUE SERVING ANOTHER APPLIANCE FRESH AIR Outside Fresh Air connection is optional It must be connected to all units installed in Mobile and Air Tight Homes R200...

Page 7: ...ature is still above 120 F 52 C Product performance The pellet stove has an advanced designed and has individual fresh air input and venting system Negative pressure burning technology causes high eff...

Page 8: ...clearance between the walls or to the top should be no less than the size in the figure Min installation clearance mm 2 Electrical The unit must be grounded earthed The grounded electrical cord should...

Page 9: ...fumes into the room The stove air input pipe diameter is 50 mm venting pipe diameter is 80 mm The total length of pipes is not longer than 3m Indoor venting pipe joint should be sealed by silicone sea...

Page 10: ...Page 10 19...

Page 11: ...l Temp and Weekly 5 TIMER BUTTON Order the start time or shutdown time of the unit Press Timer then set the period of time you needed attention the maximum is 7 hours Minimum is 1 hour After setting 5...

Page 12: ...WEEKLY PROGRAMMER Temperature Units Blower Voltage and Exhaust Voltage Restore default setting and use Diagnostic platform are also access 8 CONCEL BUTTON 9 UP AND DOWN BUTTON Three status s descript...

Page 13: ...TEMPERATURE 5 MAIN MODE HEATING POWER LEVEL IGNITOR COMBUSTION BLOWER blower AUGER CONVECTION BLOWER VACUUM SWITCH LIMIT SWITCH ON OFF STATE ADDITIONAL CONTROL MODE MAIN MODE DATE and TIME WORK STAGE...

Page 14: ...The stove will power off and the fire will be put out when the auger motor stops b The stove will power off and the fire will be put out when the convection blower stops c Auger motor stops feeding w...

Page 15: ...round the stove when it is operating 3 When installing this unit on a combustible floor for example linoleum hardwood flooring a non combustible hearth pad 15mm thickness with sufficient load bearing...

Page 16: ...way any fly ash that may have collected on the heat exchanger tubes 5 Put the ash in the ash drawer out TIMELY 6 When the appliance is not to be used for a long time it should be cleaned completely Es...

Page 17: ...ht the high temperature switches connection Change the high temperature switch D Three lights aren t bright No 220V power Pellet feeder is power off The wires of start and clock unit loose or break Ch...

Page 18: ...own the blower Clean the heat exchange tubes 8 Ash and smoke fly out Leak between the connection of convection motor and venting pipe The clean method is wrong Use silicon rubber to seal Clean the dus...

Page 19: ...Page 19 19...

Reviews: