Models and variants

TW-350    

 

Item No. 110035

TW-350 built-in 

 

Item No. 110135

TW-400   

 

Item No. 110040

TW-400 built-in 

 

Item No. 110140

Installation and setting up

Floor standing devices

The following points must be observed when setting up the free-standing models:

•   The distance from the rear wall of the devices to the next wall must be at least 100 mm.
•   The pasta cooker must not stand on a flammable surface or be built into a flammable unit.
•   The local safety, fire police and building regulations also apply.
•   The requirements of the food inspectorate must also be observed.
•   The pasta cooker is a fixed device. The roles are only intended to facilitate maintenance and cleaning work.
•  These can be removed by simply notching them as required. The device must not be moved during operation.
•   The standard height of the device is 850mm. This can be increased to 900mm with a substructure as required.
•   The power plug must be accessible after setting up the device.

Stability (standing devices)

Due to insufficient stability, the TW-350 devices must not be set up freely. They must be fastened with the angle 

plate included in the scope of delivery. Self-tapping screws can be used for fastening in the sheet metal. For wall or 

floor mounting, we recommend using screws with dowels.

Assembly substructure

•  Loosen hexagon nuts (6pcs) on the inside of the floor
•  Slide in the substructure
•   Tighten the hex nuts again.

www.gastrofrit.ch 

© Switzerland Gastrofrit AG

3

Summary of Contents for TW Series

Page 1: ...product was made entirely in Switzerland Your product has been subjected to a long term test Please note that incorrect commissioning can lead to damage Before commissioning check the exact requireme...

Page 2: ...ram the time I II III und IV 10 Temperature settings 10 Query current temperature 11 Cooking pasta 11 Reset 11 Options 11 Emptying safety process 12 Automatic basket lift 12 Energy optimization 12 Sal...

Page 3: ...only intended to facilitate maintenance and cleaning work These can be removed by simply notching them as required The device must not be moved during operation The standard height of the device is 85...

Page 4: ...ibration takes place The software version e g Gastro 8 67 can then be read on the display The 3x400V 3L N PE power connection is made with a standard compliant CE plug Technical specifications Pastame...

Page 5: ...h the plug on heater This allows the inter ior of the pans to be cleaned 2 Protective cap Art No 501000 812 Protection of the extended heater The heater can be cleaned in the appliance or dishwasher 3...

Page 6: ...rature or Menu control Keypad pasta cooker Double basket or large basket Automatic lift optional or Acoustics timer function Keypad with display Service door can be opened Device can be rolled Only in...

Page 7: ...f the deep fryer can be set between 30 and 170 C If the temperature is hig her than this set temperature the clean function is blocked 6 Automatic filtration deep fryer only Automatic filtration can b...

Page 8: ...and then the time demo mode time will be waited until the next key is simulated A program can be canceled at any time This demo mode is intended for a long term test or for a demonstration during pres...

Page 9: ...5 X Auto Filtrierung Off On Off X Auto Emptying Time 1 5 sec 500 sec 180 sec X Auto circulation Time 2 5 sec 500 sec 180 sec X Auto Filling Time 3 5 sec 500 sec 180 sec X Salinity Alarm Low 1 30 8 X...

Page 10: ...er lost through the boiling process and evaporation Press the wash away button On Off rhythm wash off runs on the factory setting level medium Switching off the wash off function Press the flush butto...

Page 11: ...hang it on the hanger to drain Warning Avoid the risk of splashing and burns Reset To restart the controller the on off and clean system buttons must be pressed simultaneously Options Emptying safety...

Page 12: ...much salt after the set time Salini ty Alarm Time the display background lighting changes to blue and an acoustic alarm may sound Salinity Alarm Sound If the salinity changes back into the valid range...

Page 13: ...lug contacts to the PT 1000 Ohm measured value PT 1000 at 25 C R 1 008 k Maintenance and customer service In the event of malfunctions contact Gastro frit AG in Rorschach Switzerland Tel 0041 71 855 8...

Page 14: ...tainless steel and can be treated with a commercially available chrome steel cleaner Daily cleaning of the heater protects the device and the performance of the heater is maintained Note If the heater...

Page 15: ...en reached H Heating power is temperature Temperature and heating power Temp Leiterplatte Temp Pt1000 Sensor Summe von 8 Messungen max 8192 4 1 Volt Temp Circuit board Temp Pt1000 Sensor Total of 8 me...

Page 16: ...r test Sensordaten werden Angezeigt Ist Temperatur Salzgehalt in Promille Leitwert Sensor data are displayed Actual temperature Salt content in per mille Conductance Buzzer and sound test Tasten I III...

Page 17: ...arkus R sch AS 001 Schweiz AS 001R0 Schema Fitting Box Friteusen Gastrofrit AG Dateiname Papierrand Heftrand nderung AS 001R0 S1 A2 A1 2 1 3 4 5 6 1 4D S1 1 2D 2 1 3 4 5 6 BEGRENZER 2 1 4 3 6 5 POWER...

Page 18: ...Anschlussschema Fittingbox Energieoptimierung www gastrofrit ch Switzerland Gastrofrit AG 18 Prinzipschaltbild f r SICOTRONIC Anschluss mit einem internen Ger teheizkreis...

Page 19: ...Anschlussschema Elektronik Gastro 8 www gastrofrit ch Switzerland Gastrofrit AG 19...

Page 20: ...0 x J J J 1 Fritteuse Standard 0 X X 0 X 0 X 1 X X X X X 0 0 x J J J 1 Fritteuse Electronic 0 X X 0 X 1 0 1 X X X X X X X 0 N J J J 2 Fritteuse Elektronik ohne Clean System ohne Korbhebe automatik 0 X...

Page 21: ...www gastrofrit ch Switzerland Gastrofrit AG 21...