background image

PREMIUM

COOKING TOPS & UNITS

ELECTRIC

MANUFACTURER'S INSTRUCTIONS

Part A: Technical data
Part B: Installation manual

- WARNING -

 Installation and repairs must be carried out by personnel approved by the manufacturer and in

accordance with current regulations and standards.

 If any modifications are made the manufacturer can accept no responsibility whatsoever.

 These appliances must be used in a well-ventilated area.

 Read the notice carefully before installation.

 The unit must be kept on its base for handling until it is in it’s final location.

N° 390 333

N

O

B

NET

9

Summary of Contents for B-B9P.BM1000

Page 1: ... approved by the manufacturer and in accordance with current regulations and standards If any modifications are made the manufacturer can accept no responsibility whatsoever These appliances must be used in a well ventilated area Read the notice carefully before installation The unit must be kept on its base for handling until it is in it s final location N 390 333 N O B NET 9 ...

Page 2: ...NSTALLATEUR MANUAL 1 Location of the identification plate 23 2 Installation General features 24 2 1 General requirements 24 2 2 Handling 24 2 3 Unpacking 24 2 4 Access to components behind the front facia 25 3 Installation Positioning 26 3 1 Cooking tops 26 3 2 Cooking units 32 4 Installation Connection 38 4 1 Electrical connection 38 4 2 Water connection 40 4 3 Drain connection 40 ...

Page 3: ...ion Leave 1 5 m cable tails MODEL B D9P FR500 B D9P FR1000 DIMENSIONS mm Height 393 393 Width 500 1000 Depth 950 950 Plate 340 x 680 340 x 680 2 plates PACKAGING mm Height 500 500 Width 600 1100 Depth 1050 1050 WEIGHT KG 77 120 TOP COMPRISES Hearth 4000 or 3500 Watts 2 4 ELECTRICITY Three phase 230V E or 400V N E Power kW 230V 3a c 7 14 400V 3Na c 8 16 Intensity max A 230V 3a c 26 3 40 3 400V 3Na ...

Page 4: ...000 DIMENSIONS mm Height 393 393 Width 500 1000 Depth 950 950 Heated surface 364 x 616 764 x 616 Usable area dm2 22 47 PACKAGING mm Height 500 500 Width 600 1100 Depth 1050 1050 WEIGHT KG 75 135 TOP COMPRISES Hearth 4000 or 3500 Watts 2 4 ELECTRICITY Three phase 230V E or 400V N E Power kW 230V 3a c 7 14 400V 3Na c 8 16 Intensity max A 230V 3a c 26 3 40 3 400V 3Na c 17 3 26 5 DRAIN Smooth stainles...

Page 5: ...DIMENSIONS mm Height 393 393 Width 500 1000 Depth 950 950 Heated surface 616 x 364 616 x 764 Usable area dm2 22 47 PACKAGING mm Height 500 500 Width 600 1100 Depth 1050 1050 WEIGHT KG 80 140 TOP COMPRISES 365mm wide plate 1 765mm wide plate 1 ELECTRICITY Three phase 230V E or 400V N E Power kW 230V 3a c 5 4 10 8 400V 3Na c 5 4 10 8 Intensity max A 230V 3a c 13 6 27 1 400V 3Na c 7 8 15 6 ELECTRICAL...

Page 6: ... cable tails AIR inlet MODEL B D9P IN63 DIMENSIONS mm Height 393 Width 500 Depth 950 PACKAGING mm Height 500 Width 600 Depth 1050 WEIGHT KG 55 TOP COMPRISES Front hob Watts 4500 Rear hob Watts 2300 AIR INLET Filter dimensions 250 x 250 ELECTRICITY Three phase 400V N E Power kW 400V 3Na c 6 8 Intensity max A 400V 3Na c 9 8 ELECTRICAL CONNECTION 630 mm from floor Non contractual document Edition 04 ...

Page 7: ...dth 500 1000 Depth 950 950 Grill dimensions 480 x 390 480 x 750 Usable area dm2 18 7 36 PACKAGING mm Height 500 500 Width 600 1100 Depth 1050 1050 WEIGHT KG 52 98 ELECTRICITY Three phase 230V E or 400V N E Power kW 230V 3a c 7 8 15 7 400V 3Na c 7 8 15 7 Intensity max A 230V 3a c 19 7 39 3 400V 3Na c 11 3 22 6 COLD WATER Pressure 2 5 6 bars Connection Flexible 21 1 2 DRAIN Smooth stainless 18mm Ø t...

Page 8: ...AGING mm Height x Depth 500 x 1050 500 x 1050 Width 600 1100 WEIGHT KG 52 98 TOP COMPRISES Number of containers GN 1 3 150 mm deep 4 5 ELECTRICITE Single phase or three phase 230V E or 400V N E Power kW 230V a c 1 5 2 3 230V 3a c 1 5 2 3 400V 3Na c 1 5 2 3 Intensity max A 230V a c 6 5 10 230V 3a c 6 5 10 400V 3Na c 6 5 10 HOT WATER Pressure 2 5 6 bars Max temperature 60 C Connection Flexible 21 1 ...

Page 9: ...P RF B D9P RFI DIMENSIONS mm Height 393 752 Width 500 500 Depth 950 950 Well Width x Length x Depth 310 x 692 x 150 310 x 692 x 150 PACKAGING mm Height 500 850 Width 600 600 Depth 1050 1050 WEIGHT KG 45 50 TOP COMPRISES Well width 310 1 1 ELECTRICITY Voltage Single phase 230V a c Power kW 1 6 Intensity max A 7 DRAIN Smooth stainless 18mm Ø tube 20cm silicone pipe Connection Provide a 50mm drain ou...

Page 10: ...P075226 500 wide P075227 1000 wide P075228 Per linear metre MODEL B D9P DN250 B D9P DN500 B D9P DN1000 B D9P DNML DIMENSIONS mm Height 393 393 393 393 Width 250 500 1000 Per linear metre Depth 950 950 950 950 PACKAGING mm Height 500 500 500 500 Width 350 600 1100 Width 100 Depth 1050 1050 1050 1050 WEIGHT KG 26 45 85 Non contractual document Edition 04 2002 EN208 ...

Page 11: ...1880 Shelf width C 277 647 777 1397 1777 PACKAGING mm Height 750 750 750 750 750 Width 600 850 1100 1600 2100 Depth 750 750 750 750 750 WEIGHT KG 28 31 34 42 50 Mobile stand height 630 5 4 3 2 1 5 3 1 4 2 4 5 2 4 3 1 2 3 5 1 1 5 3 2 1 3 4 2 5 4 CODES P075240 P075231 P075241 P075242 P075243 DIMENSIONS mm Appliance width A 500 750 1000 1500 2000 Leg centres B 380 630 880 1380 1880 Shelf width C 277 ...

Page 12: ...0 Depth 950 950 Plate 340 x 680 340 x 680 2 plates PACKAGING mm Height 1150 1150 Width 600 1100 Depth 1050 1050 WEIGHT KG 97 150 TOP COMPRISES Hearth 4000 or 3500 Watts 2 4 BASE COMPRISES Cupboard with 500 1000 ELECTRICITY Three phase 230V E or 400V N E Appliance Power kW 230V 3a c 7 14 400V 3Na c 8 16 Intensity max A 230V 3a c 26 3 40 3 400V 3Na c 17 3 26 5 Optional heated cupboard Adds to the to...

Page 13: ...ICAL connection Leave 1 5 m cable tails MODEL B B9P FR1000 FE DIMENSIONS mm Height 1023 Width 1000 Depth 950 Plate 340 x 680 2 plates PACKAGING mm Height 1150 Width 1100 Depth 1050 WEIGHT KG 180 TOP COMPRISES Hearth 4000 Watts 4 BASE COMPRISES Electric oven kW 5 1 ELECTRICITY Three phase 400V N E Power kW 400V 3Na c 21 1 Intensity max A 400V 3Na c 33 4 ELECTRICAL CONNECTION 200 mm from floor Non c...

Page 14: ...ce 364 x 616 764 x 616 Usable area dm2 22 47 PACKAGING mm Height x Depth x Width 1150 x 1050 x 600 1150 x 1050 x 1100 WEIGHT KG 85 165 TOP COMPRISES Hearths 4000 or 3500 Watts 2 4 BASE COMPRISES Cupboard with 500 1000 ELECTRICITY Three phase 230V E or 400V N E Appliance Power kW 230V 3a c 7 14 400V 3Na c 8 16 Intensity max A 230V 3a c 26 3 40 3 400V 3Na c 17 3 26 5 Optional heated cupboard Adds to...

Page 15: ...le tails MODEL B B9P PEC1000 FE DIMENSIONS mm Height 1023 Width 1000 Depth 950 Heated surface 764 x 616 Usable area dm2 47 PACKAGING mm Height 1150 Width 1100 Depth 1050 WEIGHT KG 195 TOP COMPRISES Hearth 4000 Watts 4 BASE COMPRISES Electric oven kW 5 1 ELECTRICITY Three phase 400V N E Power kW 400V 3Na c 21 1 Intensity max A 400V 3Na c 33 4 DRAIN Durite 22 Connection Prévoir collecteur mural en P...

Page 16: ...4 Usable area dm2 22 47 PACKAGING mm Height x Width x Depth 1150 x 600 x 1050 1150 x 1100 x 1050 WEIGHT KG 85 150 TOP COMPRISES 365mm wide plate 1 765mm wide plate 1 BASE COMPRISES Cupboard width 500 1000 ELECTRICITY Single phase or three phase 230V E or 400V N E Appliance Power kW 230V 3a c 5 4 10 8 400V 3Na c 5 4 10 8 Intensity max A 230V 3a c 13 6 27 1 400V 3Na c 7 8 15 6 Optional heated cupboa...

Page 17: ... cable tails MODEL B B9P IN63 DIMENSIONS mm Height 1023 Width 500 Depth 950 PACKAGING mm Height 1150 Width 600 Depth 1050 WEIGHT KG 60 TOP COMPRISES Front hob Watts 4500 Rear hob Watts 2300 BASE COMPRISES Technical cupboard width 500 AIR INLET Filter dimensions 250 x 250 ELECTRICITY Three phase 400V N E Power kW 400V 3Na c 6 8 Intensity max A 400V 3Na c 9 8 ELECTRICAL CONNECTION 200 mm from floor ...

Page 18: ...ea dm2 18 7 36 PACKAGING mm Height x Width x Depth 1150 x 600 x 1050 1150 x 1100 x 1050 WEIGHT KG 72 130 BASE COMPRISES Cupboard with 500 1000 ELECTRICITY Single phase or three phases 230V E or 400V N E Appliance Power kW 230V 3a c 7 8 15 7 400V 3Na c 7 8 15 7 Intensity max A 230V 3a c 19 7 39 3 400V 3Na c 11 3 22 6 Option heated cupboard Adds to the total power of the appliance Power kW 230V 3a c...

Page 19: ...HT KG 70 140 TOP COMPRISES Number of containers GN 1 3 150 mm deep 4 5 BASE COMPRISES Cupboard width 500 1000 ELECTRICITY Single phase or three phases 230V E or 400V N E Appliance Power kW 230V a c 1 5 2 3 230V 3a c 1 5 2 3 400V 3Na c 1 5 2 3 Intensity max A 230V a c 6 5 10 230V 3a c 6 5 10 400V 3Na c 6 5 10 Optional heated cupboard Adds to the total power of the appliance Not compatible with Thre...

Page 20: ...x Depth 500 x 950 500 x 950 Well Width x Length x Depth 310 x 692 x 150 310 x 692 x 150 PACKAGING mm Height 1150 1500 Width x Depth 600 x 1050 600 x 1050 WEIGHT KG 70 75 TOP COMPRISES Well width 310 1 1 BASE COMPRISES Cupboard with 500 1000 ELECTRICITY Single phase 230Va c Appliance Power kW 1 6 Intensity max A 7 Optional heated cupboard Adds to the total power of the appliance Power kW 1 2 Intens...

Page 21: ...ve 1 5 m cable tails MODEL B B9P DN500 B B9P DN1000 DIMENSIONS mm Height 1023 1023 Width 500 1000 Depth 950 950 PACKAGING mm Height 1150 1150 Width 600 1100 Depth 1050 1050 WEIGHT KG 65 105 TOP COMPRISES Cupboard width 500 1000 ELECTRICITY For optional heated cupboard Voltage Single phase 230V a c Power kW 1 2 Intensity max A 4 5 9 ELECTRICAL CONNECTION 200 mm from floor Non contractual document E...

Page 22: ...al compartment P075284 250 wide to be cantilevered P075283 500 wide A A MODEL B B9P CT250 B B9P CT500 DIMENSIONS mm Width 250 1000 Height 823 1023 Depth 950 950 AREA FOR SERVICES A Width 200 286 Depth 800 540 PACKAGING mm Width 350 1100 Height 950 1150 Depth 1050 1050 WEIGHT KG 20 60 BASE COMPRISES Compartment with 250 500 Non contractual document Edition 04 2002 EN235 ...

Page 23: ... 2000 Appliance width 2x500 3x500 500 1000 4x500 500 1500 2x1000 2x500 1000 Leg centres B 851 1351 1351 2 x 925 2 x 925 2 x 925 2 x 925 PACKAGING mm Included with the appliance WEIGHT KG 11 14 13 17 15 15 16 Mobile frame 200mm high 4 2 4 2 4 2 2 4 3 3 3 3 1 5 5 5 1 1 5 1 4 2 4 2 3 3 1 5 1 5 CODES P075320 P075252 P075321 P075253 P075322 P075254 P075255 DIMENSIONS mm Appliance width A 500 750 1000 1...

Page 24: ...ans 77292 MITRY MORY Cedex 1 IDENTIFICATION PLATE The identification plate is fixed onto the control panel see diagram below In any correspondence about your equipment please quote The model number Model The serial number Fab Nr The date Date Identification plate Location of the identification plate ...

Page 25: ...uests that the final recipient respects the directive with regard to recycling or reuse of the packaging materials Specifically for induction Do not position adjacent to sources of heat or where there is a risk from steam or splashes Attention Table top induction must not be put onto a closed base and the technical cupboard of free standing induction should not be used for storage Table top units ...

Page 26: ...umière Z I Mitry Compans 77292 MITRY MORY Cedex 2 4 ACCESS TO COMPONENTS BEHING THE FRONT FACIA Undo the screws under the facia Lift the facia upward and pull it forwards It is possible to hook the facia on the unit in the open position To re assemble reverse the above operations ...

Page 27: ... Width 1000 Width 1500 A 500 750 1000 1500 C 420 670 920 1420 Each bracket must be able to support a force of 400 deca Newtons All units 500 1000 or 1500mm wide have 2 brackets It is advisable when fixing to a concrete wall to respect the following recommendations The reinforced concrete wall should be at least 23 Mega Pascal DTU norm Use heavy duty 12 x 40 rawlplugs 6 are required for cooking equ...

Page 28: ... Fit the retaining plates and M12 nuts without tightening them fully Fit the height adjustment screws Adjust to height 900 mm and level left to right LEVEL Fit the screws for front to back adjustment Adjust the level front to rear using the lower screws LEVEL Tighten and fit the lock nuts Follow the same proceedure for subsequent units Bracket Plate Screws Screws ...

Page 29: ... X 16 bolt a 5mm ø washer Having first removed the front facia see section 2 connect using 2 HM5 X 16 bolts 5mm ø washers The left hand side panels are threaded 3 1 2 ASSEMBLY OF TOPS ON FIXED OR MOBILE STANDS Put units on stands as per the following table 5 4 3 2 1 5 3 1 4 2 4 5 2 4 3 1 2 3 5 1 1 5 3 2 1 3 4 2 5 4 Table of sizes Length A 500 750 1000 1500 2000 Length B 380 630 880 1380 1880 ...

Page 30: ...op of the stand Fix unit to the stand at the front and back using four HM5 x 10mm bolts 5mm Ø washers Cage nuts are fixed to the bottom of the unit Bolt units together at the back through the flue vents with one HM5 X 16 bolt a 5mm ø washer Having first removed the front facia see section 2 connect using 2 HM5 X 16 bolts 5mm ø washers Fixing hole Fixing bracket ...

Page 31: ...77292 MITRY MORY Cedex 3 1 3 ASSEMBLY OF TOPS ON REFRIGERATED BASE Fix units onto bases as indicated 1 1 5 5 4 3 2 3 4 2 1 5 1 5 3 4 2 3 4 2 3 5 4 1 5 1 2 3 4 2 Fix unit to the stand at the front and back using four HM5 x 10mm bolts 5mm Ø washers Cage nuts are fixed to the bottom of the unit Fixing holes ...

Page 32: ...ocial Rue des Frères Lumière Z I Mitry Compans 77292 MITRY MORY Cedex Bolt units together at the back through the flue vents with one HM5 X 16 bolt a 5mm ø washer Having first removed the front facia see section 2 connect using 2 HM5 X 16 bolts 5mm ø washers ...

Page 33: ...e the unit on the leg frame the back of the unit and the rear of the leg frame should be roughly in line the leg frame is symetrical front to back Push the unit back until hooks in the bottom locate in the 25mm square holes provided Repeat for each item to be fitted on the common leg frame At the front units should be secured to the leg frame using two HM 5 x 16 bolts 5mm Ø washers Hook Hole ...

Page 34: ...e vents with one HM5 X 16 bolt a 5mm ø washer Having first removed the front facia see section 2 connect using 2 HM5 X 16 bolts 5mm ø washers 3 2 2 ASSEMBLY OF UNITS ON INDIVIDUAL STANDS Bolt units together at the back through the flue vents with one HM5 X 16 bolt a 5mm ø washer Having first removed the front facia see section 2 connect using 2 HM5 X 16 bolts 5mm ø washers ...

Page 35: ...Rue des Frères Lumière Z I Mitry Compans 77292 MITRY MORY Cedex Fix units together behind the front feet with a clamp a Place the clamp opposite the slots b Tighten manually as far as possible c Finish tightening with HM5 x 60 bolts Left hand unit Right hand unit ...

Page 36: ... Length of suite Mur Top view A technical compartment is required if the stop cocks isolating valves or the governors are to be housed in the suite Three solutions are possible 1 Neutral top on a 250mm technical compartment 2 A 500mm technical cupboard with any type of cooking or neutral top possible except Induction 3 Technical compartment at the end of the suite 250 wide with neutral top access ...

Page 37: ...A Top view A technical compartment is required if the stop cocks isolating valves or the governors are to be housed in the suite Three solutions are possible 1 Neutral top on a 250mm technical compartment 2 A 500mm technical cupboard with any type of cooking or neutral top possible except induction 3 Technical compartment at the end of the suite 250 wide with neutral top access door in the end Zon...

Page 38: ... cladding for suite factory fitted to stainless plinth Fixing arm Fixing arm support S S plinth assembly Detail adjustment Assembly of two plinth sub assemblies Stainless plinth adjustment screw Fixing arm support Template to fit into the 3 x 20 cutouts in the front and rear of the support arms Adjust the level using the adjustment screw provided see above plan Push the unit back until the hooks i...

Page 39: ...tion as indicated below according to power and voltage See section Technical data DESIGNATION 230 V a c 230 V 3 a c 400 V 3N a c Table top Radiant hobs in 500 4 x 6 mm 2 5 x 2 5 mm 2 Table top Radiant hobs in 1000 4 x 6 mm 2 5 x 6 mm 2 Table top Solid top in 500 4 x 6 mm 2 5 x 2 5 mm 2 Table top Solid top in 1000 4 x 6 mm 2 5 x 6 mm 2 Table top Plancha in 500 4 x 2 5 mm 2 5 x 2 5 mm 2 Table top Pl...

Page 40: ...al cupboard in 500 4 x 4 mm 2 5 x 2 5 mm 2 Bar grill on neutral cupboard in 1000 4 x 6 mm 2 5 x 4 mm 2 Bain marie on neutral cupboard in 500 3 x 2 5 mm 2 4 x 2 5 mm 2 5 x 2 5 mm 2 Bain marie on heated cupboard in 500 3 x 2 5 mm 2 4 x 2 5 mm 2 5 x 2 5 mm 2 Bain marie on neutral cupboard in 1000 3 x 2 5 mm 2 4 x 2 5 mm 2 5 x 2 5 mm 2 Bain marie on heated cupboard in 1000 3 x 4 mm 2 4 x 4 mm 2 5 x 4 ...

Page 41: ...ing to the type of appliance See Technical data section Minimum pressure 2 5 bar max 6 bar Maximum temperature for the hot water 60 C Flexible connection 21mm 1 2 diameter Fit a local stop cock Cooking top Cooking unit Flexible hose inlet for water 4 3 DRAIN CONNECTION Discharge hose diameter 22 mm Collection pipework in 50 mm plastic Cooking top Cooking unit Max 160 Min 110 ...

Page 42: ...E DRAINS MUST NOT BE CONNECTED DIRECTLY TO WASTE AN AIR BREAK IS REQUIRED This avoids the possiblity of waste water returning to a bain marie for example The drainage pipework should incorporate a trap to avoid odours Note It is possible to fix the drain pipework to the underside of the units this can be useful for an island suite Fixing drain pipe to the equipment 160 ...