Page 26
N
O
B
NET
BONNET CIDELCEM GRANDE CUISINE
Siége social:
Rue des Frères Lumière - Z.I Mitry Compans
77292 MITRY MORY Cedex
3. INSTALLATION: POSITIONING
3.1 COOKING TOPS
3.1.1 ASSEMBLY WHEN CANTILEVERED FROM A WALL
Procedure
- Fix the wall brackets very solidly to the wall in the positions indicated below.
WALL
Table of the anchorage points for wall brackets.
Width 500
Width 750
Width 1000
Width 1500
A
500
750
1000
1500
C
420
670
920
1420
Each bracket must be able to support a force of 400 deca Newtons. All units (500, 1000 or
1500mm wide) have 2 brackets.
It is advisable when fixing to a concrete wall to respect the following recommendations:
- The reinforced concrete wall should be at least 23 Mega Pascal (DTU norm).
- Use heavy duty 12 x 40 rawlplugs (6 are required for cooking equipment).
- The required hole for such rawlplugs should be 12mm diameter and 72mm deep (NOTE: the
minimum distance between a rawlplug hole and any edge of the wall must be at least 95mm).