Moving devices
Moving the pasta cooker with hot water in the basin or
in the collecting container is not permitted! Likewise,
the removal of the hot water in the filled collecting
container. The water must be allowed to cool to at
least 60 ° C.
Extended display
This display is only intended for service cases and
not for the customer!
With the extended display, the target and actual
values of the temperature, calibration parameters and
the heating power can be viewed on various display
pages.
Switch to the extended display:
To switch to the extended display,
the buttons, must be pressed simultaneously for a
short time and the current temperature will appear on
the display. During this display, the „plus“ key must be
held down and the first page of the extended display
appears. If you want to view the data from the oil
sensor or salt sensor, the „minus“ key must be pressed.
Change display pages: To select the other display
pages, briefly press the „plus“ button. Exiting the
extended display: Press the „minus“ key.
Target temperature: „>“ means that the temperature
has not yet been reached:
- “H:“ Heating power is temperature
Temperature and heating power:
Temp. Leiterplatte Temp. Pt1000-Sensor
Summe von 8 Messungen (max. 8192 -> 4.1 Volt)
Temp. Circuit board Temp. Pt1000-Sensor
Total of 8 measurements (max. 8192 -> 4.1 volts)
Temperature display:
Ref. Widerstand 1240R Ref. Widerstand 1740R
Summe von 8 Messungen (max. 8192 -> 4.1 Volt)
Ref. Resistor 1240R Ref. Resistor 1740R
Total of 8 measurements (max. 8192 -> 4.1 volts)
Display pages with the „minus“ key:
Daten vom Ölsensor werden Angezeigt.
Ölqualität 3-30%
Temperatur vom Ölsensor
Data from the oil sensor are displayed.
Oil quality 3-30% temperature from the oil sensor
Oelsensor: (for deep fryers)
Sensordaten werden Angezeigt. Ist-Temperatur
Salzgehalt in Promille
Leitwert
Sensor data are displayed.
Actual temperature
Salt content in per mille
Conductance
Key assignment in test mode
The various test states can be
called up with the key. For some tests, entries can still
be made, this is done
this is done with the buttons and
buttons „plus“ and „minus“.
To exit test mode, press the „on / off“ button.
Test pages:
keyboard test:
Tasten I-IV und die Tasten CleanSystem /
Wasserfüllung und Oilcheck / Abschwemmung
Buttons I-IV and the buttons CleanSystem /
water filling and Oilcheck / flushing
Temperature test:
Temperatur
Temperatur
Leiterplatte
Pt1000-Sensor
DIP switch and relay test:
www.gastrofrit.ch
© Switzerland Gastrofrit AG
15