background image

Automatic basket lift

The automatic basket lifting function automatically 

lifts the pasta basket out of the water when the time 

has elapsed.

 (The time is stored in which

press the respective button for 10 seconds) As soon 

as the time has been programmed, the respective 

program button can be pressed. With the pasta cooker 

there are 2 programs on the right and 1 program on 

the left and a common button for the right and left. 

By pressing the respective button, the corresponding 

stroke moves down and up again after the time has 

elapsed. For example, if you have pressed the Program 

1 button once but wanted to press lift 2, you don‘t 

have to wait until it comes up again, simply press lift 1 

again and the process is canceled.

When the pasta cooker is switched on, the lifting 

motor starts up. When it is switched off, it retracts 

accordingly to close the lid.

Energy optimization

There are two different types of energy optimization 

controls. Energy optimization light and energy optimi-

zation with ABCD interface.

With the energy optimization light, a relay (break 

contact) must be provided on site. You can request 

detailed documents from us.

Salt check

With this option the salt content of the water can be 

checked and the customer has a relief for a constant 

quality of the pasta.

With the TW, the monitoring of the salt content (salini-

ty alarm) can be set between 1 ‰ and 30 ‰. (Default 

values: Low = 8 ‰ and High 12 ‰). If this value is ex-

ceeded or not reached, the display background color 

changes after the set time (time 1 - 60 seconds). 

•   If there is too little salt, after the set time (Salinity 

Alarm Time), the display background lighting 

changes to purple and an acoustic alarm (Salinity 

Alarm Sound) may sound.

•  •If there is too much salt, after the set time (Salini-

ty-Alarm-Time), the display background lighting 

changes to blue and an acoustic alarm may sound 

(Salinity-Alarm-Sound).

•  •If the salinity changes back into the valid range, 

the background lighting changes to the normal 

color and the acoustic alarm is ended.

The salt content is displayed with the “+” and “-” key 

combination and the alarm is reset by pressing the 

“+” key.

A salt concentration of 1- 1.2% is perceived as optimal 

(10-12g per 1 liter of water)

The interval of the acoustic alarm is 10sec. When ex-

ceeding or falling below the limit values, different tone 

sequences sound ...

•  Off: 

no acoustic alarm

•  On: 

acoustic alarm when the TW is switched on.

•  Temp: 

Acoustic alarm when the TW is switched on and 

the temperature is> 90 ° C

•  Lift: 

Acoustic alarm when the TW is switched on, the 

temperature> 90 ° C and a HUB is active.

Service functions

Change O-rings on the attachable heater 

Description and function

Please make sure, however, that the O-ring (black ring) 

cannot be damaged by knives or other sharp objects. 

A defective seal means that the heating is no longer 

tight and the water runs out and drips into the service 

room. The removable heating element is provided 

with an O-ring (see picture) which prevents water from 

leaking into the interior. The permanent heat load can 

cause the O-ring to become brittle and its function 

can only be of limited service. This sealing ring can 

be exchanged easily. Manufacturer recommenda-

tion: Replace this seal annually. With a maintenance 

contract LongLife or LongLifePlus, we as the company 

Gastrofrit®AG will carry out this measure. You can 

also instruct the manufacturer to have these replaced 

during a six-monthly check. You can order the O-ring 

or more detailed information on the maintenance con-

tracts by c41 71 855 8070 or info.gastrofrit.ch.

Remove the old O-ring:

    

New O-ring :

„„by hand „

„Without force“

www.gastrofrit.ch 

© Switzerland Gastrofrit AG

12

Summary of Contents for TW Series

Page 1: ...product was made entirely in Switzerland Your product has been subjected to a long term test Please note that incorrect commissioning can lead to damage Before commissioning check the exact requireme...

Page 2: ...ram the time I II III und IV 10 Temperature settings 10 Query current temperature 11 Cooking pasta 11 Reset 11 Options 11 Emptying safety process 12 Automatic basket lift 12 Energy optimization 12 Sal...

Page 3: ...only intended to facilitate maintenance and cleaning work These can be removed by simply notching them as required The device must not be moved during operation The standard height of the device is 85...

Page 4: ...ibration takes place The software version e g Gastro 8 67 can then be read on the display The 3x400V 3L N PE power connection is made with a standard compliant CE plug Technical specifications Pastame...

Page 5: ...h the plug on heater This allows the inter ior of the pans to be cleaned 2 Protective cap Art No 501000 812 Protection of the extended heater The heater can be cleaned in the appliance or dishwasher 3...

Page 6: ...rature or Menu control Keypad pasta cooker Double basket or large basket Automatic lift optional or Acoustics timer function Keypad with display Service door can be opened Device can be rolled Only in...

Page 7: ...f the deep fryer can be set between 30 and 170 C If the temperature is hig her than this set temperature the clean function is blocked 6 Automatic filtration deep fryer only Automatic filtration can b...

Page 8: ...and then the time demo mode time will be waited until the next key is simulated A program can be canceled at any time This demo mode is intended for a long term test or for a demonstration during pres...

Page 9: ...5 X Auto Filtrierung Off On Off X Auto Emptying Time 1 5 sec 500 sec 180 sec X Auto circulation Time 2 5 sec 500 sec 180 sec X Auto Filling Time 3 5 sec 500 sec 180 sec X Salinity Alarm Low 1 30 8 X...

Page 10: ...er lost through the boiling process and evaporation Press the wash away button On Off rhythm wash off runs on the factory setting level medium Switching off the wash off function Press the flush butto...

Page 11: ...hang it on the hanger to drain Warning Avoid the risk of splashing and burns Reset To restart the controller the on off and clean system buttons must be pressed simultaneously Options Emptying safety...

Page 12: ...much salt after the set time Salini ty Alarm Time the display background lighting changes to blue and an acoustic alarm may sound Salinity Alarm Sound If the salinity changes back into the valid range...

Page 13: ...lug contacts to the PT 1000 Ohm measured value PT 1000 at 25 C R 1 008 k Maintenance and customer service In the event of malfunctions contact Gastro frit AG in Rorschach Switzerland Tel 0041 71 855 8...

Page 14: ...tainless steel and can be treated with a commercially available chrome steel cleaner Daily cleaning of the heater protects the device and the performance of the heater is maintained Note If the heater...

Page 15: ...en reached H Heating power is temperature Temperature and heating power Temp Leiterplatte Temp Pt1000 Sensor Summe von 8 Messungen max 8192 4 1 Volt Temp Circuit board Temp Pt1000 Sensor Total of 8 me...

Page 16: ...r test Sensordaten werden Angezeigt Ist Temperatur Salzgehalt in Promille Leitwert Sensor data are displayed Actual temperature Salt content in per mille Conductance Buzzer and sound test Tasten I III...

Page 17: ...arkus R sch AS 001 Schweiz AS 001R0 Schema Fitting Box Friteusen Gastrofrit AG Dateiname Papierrand Heftrand nderung AS 001R0 S1 A2 A1 2 1 3 4 5 6 1 4D S1 1 2D 2 1 3 4 5 6 BEGRENZER 2 1 4 3 6 5 POWER...

Page 18: ...Anschlussschema Fittingbox Energieoptimierung www gastrofrit ch Switzerland Gastrofrit AG 18 Prinzipschaltbild f r SICOTRONIC Anschluss mit einem internen Ger teheizkreis...

Page 19: ...Anschlussschema Elektronik Gastro 8 www gastrofrit ch Switzerland Gastrofrit AG 19...

Page 20: ...0 x J J J 1 Fritteuse Standard 0 X X 0 X 0 X 1 X X X X X 0 0 x J J J 1 Fritteuse Electronic 0 X X 0 X 1 0 1 X X X X X X X 0 N J J J 2 Fritteuse Elektronik ohne Clean System ohne Korbhebe automatik 0 X...

Page 21: ...www gastrofrit ch Switzerland Gastrofrit AG 21...

Reviews: