![GARO ENTITY PRO Installation And Operations Download Page 66](http://html2.mh-extra.com/html/garo/entity-pro/entity-pro_installation-and-operations_3595309066.webp)
Connection group A1A
Connection group A1
Connection group A1A:2
100A
32A
50A
80A
CS 2
CS 3
CS 4
CS 1
I max =
Fuse size (in this case 50A)
I monitored =
I
cs2
+
I
cs3
+
I
cs4
I max =
Fuse size (in this case 80A)
I monitored =
Measured current in fuse
by LI 2, through CT.
I max =
Fuse size (in this case 100A)
I monitored =
Measured current in fuse
by LI 1 through HAN
interface.
Incomming current/Main fuse
Note :
Only CS loads in this circuit, no need for any LI or dedicated energymeter.
Smart Utility
energy meter (HAN)
LI 1
LI 2
CT 100A/333mV
16A
10A
3-level Connection group (CG)
Power monitoring structure
66