CAUTION
If the charging station is set up without any internet
connectivity, it will allow charging at maximum current
defined by the attached charging unit. The default
setting is 16 A. Can be adjusted as parameter.
4.12.13 TO INSTALL A PROTECTION COVER
The protection cover is used to protect the installation
bracket if a charging unit should not be attached from
the start or temporary removed. When the protection
cover is installed, the charging station is protected from
damage before installation of the charging unit.
1. Attach the protection cover to the installation
bracket.
2. Tighten the screws with a Torx TX20 until the
protection cover is tight against the installation
bracket (max. 2,9 Nm).
4.12.14 TO ATTACH THE CHARGING UNIT TO THE
INSTALLATION BRACKET
1. If applicable, install the ethernet cable(s) in the
ethernet ports on the charging unit.
2. Install the control cable to the control cable port on
the charging unit.
3. Attach the charging unit to the installation bracket.
Press equally on the charging unit with both hands.
CAUTION
Make sure that no cables get pinched and that the
charging unit can meet the edges of the installation
bracket.
TX20
35
Summary of Contents for ENTITY PRO
Page 1: ...GAROEntityProinstallationand operation GARO Entity Pro installation and operation...
Page 4: ......
Page 8: ......
Page 10: ......
Page 74: ......
Page 84: ......
Page 90: ......
Page 91: ...EC DECLARATION OF CONFORMITY 91 EC Declaration of conformity...