Messages
Message
Description
Action
CROSSFILL ERROR-
Crossfi ll is inoperative.
See CRG for crossfi lled
items.
An error was detected
during unit-to-unit
communication of data.
This can be caused by
problems with HSDB
wiring or by either GTN
needing service. See the
items listed in the System
section of this manual for
crossfi lled items.
Start both GTNs in
Confi guration Mode and
ensure that both GTNs are
confi gured for crossfi ll.
Contact dealer for service.
CROSSFILL ERROR-
GTN Navigation DB
mismatch. See CRG for
crossfi lled items.
The navigation databases
do not match between
GTNs resulting in a loss of
communication between
two units.
Check the specifi ed
database version of both
GTNs and ensure it is up-to-
date. Updated the specfi ed
databse if needed.
CROSSFILL STATUS-
Crossfi ll is turned off.
DATABASE-
Chart function
unavailable.
The GTN is confi gured for
ChartView or FliteCharts
and chart verifi cation has
failed.
Contact dealer for service.
DATABASE-
Chart database valid
until [DATE].
The GTN is confi gured for
ChartView or FliteCharts
and the chart database
has or is about to expire.
Verify chart database
expiration date on the
System – System Status
page. Update chart
database if necessary for
operations.