28
1 - COM
190-00356-00 Rev B
Remote Frequency Selection Control
On units configured for remote Com frequency
recall*, pressing the remote recall switch will load the
next preset Com frequency into the unit’s Standby fre-
quency box and display a temporary pop-up window
with the current Preset ID number—e.g., Preset 1 or
Preset 12. The remote recall switch can be pressed
multiple times to scroll the entire preset frequency
list through the Standby frequency box (the list will
“wrap” from the bottom of the list back up to the top,
skipping any empty preset positions).
* Preset Com Frequencies are only available with SW
Version 3.00, or later.
The standby frequency isn’t activated until a Com
flip flop switch (either remote- or bezel-mounted) is
pressed. Remote Frequency Selection only functions
on units configured for a remote Com Frequency
recall switch. See
Aux Pages - Setup 2 Page - Preset Com
Frequencies
for instructions on storing preset Com
frequencies.
Remote Frequency Selection
190-00356-00_0B.indd 28