background image

Part # 4532435 Rev 02 (Sep 9/14)

Page 8

INSTALLATION Continued

6.  When pressure testing the gas supply piping to a 

maximum of ½ psi (14” WC, 34.9mbar), the appliance 
must be isolated from the supply line by closing the 
manual shut-off  valve.

7.  To ensure optimal operation of this unit, it is 

recommended that the dynamic gas supply pressure into 
the appliance regulator is a minimum of 1” WC(2.5mbar) 
higher than the pressure stated on the rating plate.

Start Up

1.  Inside the unit, ensure the burners are in the correct 

position and the shields hanging under the burners have 
not rotated out of position during transit.

2.  Install cast radiants over each burner and place the 

cooking grates in position on the unit.

3.  Ensure the gas supply to the appliance is open and the 

unit is connected to the power supply.  Activating the 
one or two power switches on the right leg operates the 
unit.

4.  Check all gas connections for leaks using a soap solution.  

Do not use an open fl ame to check for leaks.  Be sure 
to inspect connections outside and inside the unit (ie: 
valves, manifold fi ttings and connections in the left leg 
channel) to make certain all connections are gas tight 
after shipping.

5.  Verify the unit is running at the pressure stated on the 

rating plate as follows:

FOR HEEGM24 & 36 SIZE UNITS

•  Connect a manometer to the test spigot on the 

manifold.  

•  Turn on the unit and adjust the burners so that they are 

all set to high.

•  If necessary, adjust the pressure so that the reading 

on the manometer matches the pressure value stated 
on the rating plate.  To adjust the pressure, access and 
rotate the pressure adjustment screw on the regulator 
installed at the appliance.

FOR HEEGM48 & 60 SIZE UNITS

•  Connect a manometer to the test spigot on the LEFT 

manifold.

•  Turn on the LEFT side of the unit only (by activating 

the left switch) and adjust the burners so that they are 
all set to high.

•  If necessary, adjust the pressure so that the reading 

on the manometer matches the pressure value stated 
on the rating plate.  To adjust the pressure, access and 
rotate the pressure adjustment screw on the regulator 
installed at the appliance.

6.  Inspect the fl ame of each burner to determine whether 

adjustments to the burner air shutter are necessary.  
Adjustments are made by loosening the air shutter screw; 
rotating the shutter and re-tightening the screw.  If the 
tips of the fl ame appear too yellow, the shutter should 
be turned to allow MORE air to enter the burner cavity.  If 
the fl ames appear to be lifting off  the burner ports, the 
shutter should be turned to allow LESS air to enter the 
burner cavity.

Summary of Contents for HEEGM24CE

Page 1: ... OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE THIS PRODUC...

Page 2: ...5 Introduction 5 Damage Check 5 Rating Plate 5 INSTALLATION 6 General 6 Australia Specific Regulation 6 Positioning and Setup 6 Optional Stand 6 Air Supply and Ventilation 6 Electrical Connection 7 Gas Connection 7 Start Up 8 Operation 9 USE AND CARE 9 Warnings 10 Optional Equipment 11 CLEANING AND MAINTENANCE 12 General 12 Warnings 12 Cleaning During Operations 12 Daily Cleaning 13 Weekly Periodi...

Page 3: ...000 ft 610m Gas inlet pipe is 3 4 NPT on all models NPT to ISO adapter gas pressure regulator supplied with all models Natural Propane HEEGM24CE 4 17 0 61 2 15 2 54 9 HEEGM36CE 6 25 5 91 8 22 9 82 3 HEEGM48CE 9 38 2 137 7 34 3 123 4 HEEGM60CE 11 46 7 168 3 41 9 150 9 CE Approved Gas Categories Country Gas Category Gas Type Pressure mbar AT CH CZ DK ES FI GB GR IE IT NO PT SE LU I2H G20 20 DE I2E G...

Page 4: ... NPT GAS INLET NPT TO ISO ADAPTER SUPPLIED 28 925in 735mm LEG DEPTH 7 850in 199mm VALVE HEIGHT 1 3 RAIL DEPTH STUB RAIL DEPTH DIMENSIONS AND SPECIFICATIONS continued Dimensions Width Measurements Model Cook Width C Leg Pitch D Overall Width E Grease Tray HEEGM24CE 19 906in 506mm 14 124in 359mm 23 500in 597mm SINGLE HEEGM36CE 29 906in 760mm 24 124in 613mm 33 500in 851mm SINGLE HEEGM48CE 43 906in 11...

Page 5: ...designed specifically for holding warming fajita pans in lieu of two reversible or single sided grates N C Equipment Stands are available see HEMST specification sheet 10 foot 3 meters power cord with CEE7 7 plug head or BS1363 A plug head Standard and Optional Features PRE INSTALLATION INSTALLATION MAINTENANCE AND REPAIRS SHOULD BE DONE BY AN AUTHORIZED SERVICE AGENCY FOR A LIST OF AUTHORIZED SER...

Page 6: ...hims for countertop installation IT IS IMPERATIVE THAT THE UNIT IS PROPERLY LEVELED DURING INSTALLATION TO ENSURE OPTIMAL PERFORMANCE OF THE PRODUCT 3 For cleanliness the unit can be sealed to the mounting surface with silicone If sealing the unit to the surface avoid sealing lower stainless steel panels to the surface as these may need to be removed for service 4 Position the appliance in an area...

Page 7: ...her foreign matter will not clog pilots valves and or controls If necessary purge new piping prior to connecting the appliance Use pipe sealant that is certified for use with liquefied petroleum for new joints and or connections where sealant is required 3 Air movement should be checked during installation There must be adequate air intake into the building to compensate for the amount of air remo...

Page 8: ...unit is running at the pressure stated on the rating plate as follows FOR HEEGM24 36 SIZE UNITS Connect a manometer to the test spigot on the manifold Turn on the unit and adjust the burners so that they are all set to high If necessary adjust the pressure so that the reading on the manometer matches the pressure value stated on the rating plate To adjust the pressure access and rotate the pressur...

Page 9: ...ockout mode turn the power switch to the OFF position and remove power to the unit USE AND CARE Ignition can be attempted again by turning the power switch to the ON position and restoring power to the unit IMPORTANT Wait 5 minutes between ignition attempts If ignition fails again and the unit goes back into lockout turn the power off and have a qualified service technician inspect the unit 3 Mode...

Page 10: ...front rail grease tray handle and valve panel may get hot enough to burn skin Do not operate the broiler without the side shields in place as it may adversely affect the performance of the unit and or allow heat to migrate to neighboring equipment property causing damage The shields also prevent the cooking grates from sliding off the side of the unit when they are placed in the elevated position ...

Page 11: ...s on one appliance is prohibited and could void your warranty The fajita pan grate has been designed to accommodate only one fajita pan per slot in either the vertical or horizontal position as shown in the image below Placing multiple fajita pans in one slot and or placing fajita pans flat on this grate or the standard grate may cause damage to the broiler and could void your warranty THE FAJITA ...

Page 12: ...f grease debris The cooking grates on this unit are shielded from open flame by the radiants Attempting to burn off grease debris will likely have the opposite effect and cause the grease debris to stick even more When cleaning cast iron components such as the cooking grates radiants and burners do not handle these components roughly Dropping them on the floor or in the sink may cause them to crac...

Page 13: ...ean the side shields with a hot soapy solution and or a food safe liquid cleaner designed to clean stainless steel CLEANING AND MAINTENANCE continued 2 Remove the burners and hanging shields from the unit as follows Remove the pins at the rear of the burner Lift the burner peg up and out of the bracket at the rear Slide the burner back and off the orifice Angle the front of the burner down and the...

Page 14: ... requires service contact your local authorized Manitowoc service agency All repairs must be performed by a qualified technician using genuine Garland replacement parts or risk negating the warranty For a list of Authorized Service Agents or to view a Genuine Parts list for your appliance visit the Manitowoc Foodservice website at http www ManitowocFoodservice com Refer to the rating plate when ca...

Page 15: ...Part 4532435 Rev 02 Sep 9 14 Page 15 NOTES ...

Page 16: ...ation and Operation Manual GARLAND COMMERCIAL RANGES LTD 1177 Kamato Rd Mississauga ON L4W 1X4 Canada www Garland Group com MANITOWOC FOODSERVICE Sales and Service www ManitowocFoodservice com Part 4532435 Rev 02 09 09 14 2013 Garland Commercial Ranges Ltd ...