INSTALLATION continued

“ALL DOWNSTREAM BURNER AND PILOT VALVES 
MUST BE TURNED OFF PRIOR TO RESTORING THE 
GAS SUPPLY.  AFTER AN EXTENDED SHUT OFF, PURGE 
BEFORE RESTORING GAS.”

1.  A manual gas shut-off  valve must be installed in the gas 

supply line ahead of the appliance for safety and ease 
of future service.  The shut-off  valve should be located 
such that it can be reached quickly in the event of an 
emergency.  The shut-off  valve is normally supplied by 
the installer.

2.  This unit is shipped with a gas pressure regulator.  It must 

be installed at the appliance prior to connecting the 
equipment to the gas line. Each appliance must have its 
own pressure regulator.  Be sure to install the regulator 
according to the gas fl ow direction and verify that the 
pressure marking corresponds with the gas type.  Failure 
to install a regulator will void the equipment warranty.

PRIOR TO CONNECTING THE REGULATOR, CHECK THE GAS 
SUPPLY LINE PRESSURE.  THE REGULATOR SUPPLIED WITH 
THE UNIT IS RATED FOR A MAXIMUM OF ½ PSI (14” WC, 
34.9mbar).  IF THE GAS SUPPLY LINE PRESSURE EXCEEDS 
THIS MAXIMUM, A STEP DOWN REGULATOR WILL BE 
REQUIRED AND MUST BE INSTALLED IN ACCORDANCE WITH 
LOCAL CODES.

THE RED AIR-VENT CAP IS PART OF THE REGULATOR AND 
SHOULD NOT BE REMOVED, UNLESS LOCAL CODES REQUIRE 
EXTERNAL VENTING.  IF EXTERNAL VENTING IS REQUIRED, 
INSTALL IN ACCORDANCE WITH LOCAL CODES.

3. A certifi ed fl exible gas hose and quick disconnect 

assembly with suitable strain relief is recommended for 
connection from the gas supply line to the unit.  This will 
allow the unit to be moved for future service.

FLEXIBLE HOSES & QUICK DISCONNECT DEVICES MUST 
COMPLY WITH ALL LOCAL AUTHORITIES AND CODES.  

Adequate means must be provided to limit the movement 
of the appliance without depending on the connector and 
the quick-disconnect device or its associated piping.

4.  Only connect this unit to the type of gas shown on the 

rating plate.  Operating this unit with the wrong gas type 
can result in abnormal performance, property damage, 
injury or death.

5.  Ensure that any new piping, joints and connections have 

been made in a clean manner, so that dirt, threading 
chips and/or other foreign matter will not clog pilots, 
valves and/or controls.  If necessary, purge new piping 
prior to connecting the appliance.  Use pipe sealant that 
is certifi ed for use with liquefi ed petroleum, for new 
joints and/or connections, where sealant is required.

3.  Air movement should be checked during installation.  

There must be adequate air intake into the building 
to compensate for the amount of air removed by the 
ventilation system.  Without a proper balance, abnormal 
atmospheric pressure will occur, aff ecting burner and 
appliance performance.  If air movement is a concern, 
adjustments should be made to correct the problem by a 
qualifi ed technician.

HAVING DIFFICULTY OPENING DOORS THAT EXIT THE 
BUILDING, IS AN INDICATION THAT THE BUILDING HAS A 
PROBLEM WITH AIR MOVEMENT.

4.  Do not permit fans to blow directly at the appliance and 

avoid opening windows behind or beside the appliance.  
This can create air cross-currents and/or excessive drafts 
that interfere with the operation of the unit.

Electrical Connection 

DISCONNECT THE POWER SUPPLY BEFORE SERVICING.

Standard units are supplied with a 10 feet (3 meter) power 
cord with appropriate strain relief and either a CEE7/7, 
BS1363/A or no plug. If no plug is supplied, have a certifi ed 
technician install the appropriate plug in accordance with 
local regulations. A suitable outlet is required in close 
proximity to the appliance. Consult a certifi ed technician if 
you have concerns about the suitability of the outlet.

DO NOT USE AN EXTENSION CORD TO CONNECT THIS UNIT 
TO A POWER SUPPLY.  DO NOT USE THIS APPLIANCE IF THE 
POWER CORD IS DAMAGED.  DO NOT ATTEMPT TO REPAIR A 
DAMAGED POWER CORD.  TAKE CARE NOT TO EXPOSE THE 
POWER CORD TO HEAT OR SHARP EDGES.

Gas Connection

ENSURE THE GAS METER AND GAS PIPING ARE SIZED 
CORRECTLY FOR THE AMOUNT OF GAS FLOW AND 
PRESSURE THAT WILL BE NEEDED TO RUN ALL APPLIANCES 
IN THE KITCHEN.  UNDERSIZED GAS PIPING INTO THE 
KITCHEN MAY AFFECT THE PERFORMANCE OF THIS AND/OR 
OTHER EQUIPMENT.  IF IN DOUBT, CONSULT YOUR LOCAL 
GAS AUTHORITY.

A MANUAL OR AUTOMATIC ISOLATION VALVE MUST BE 
INSTALLED ON THE GAS SUPPLY TO THE KITCHEN FOR 
ACCESS IN THE EVENT OF AN EMERGENCY.  THE MANUAL 
VALVE OR AUTOMATIC VALVE ACCESS POINT SHOULD BE 
READILY ACCESSIBLE AND LOCATED EITHER OUTSIDE THE 
KITCHEN OR CLOSE TO AN EXIT.  POST THE FOLLOWING 
NOTICE AT THE MANUAL VALVE OR AUTOMATIC VALVE 
ACCESS POINT:

Summary of Contents for HEEGM24CE

Page 1: ... OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE THIS PRODUC...

Page 2: ...5 Introduction 5 Damage Check 5 Rating Plate 5 INSTALLATION 6 General 6 Australia Specific Regulation 6 Positioning and Setup 6 Optional Stand 6 Air Supply and Ventilation 6 Electrical Connection 7 Gas Connection 7 Start Up 8 Operation 9 USE AND CARE 9 Warnings 10 Optional Equipment 11 CLEANING AND MAINTENANCE 12 General 12 Warnings 12 Cleaning During Operations 12 Daily Cleaning 13 Weekly Periodi...

Page 3: ...000 ft 610m Gas inlet pipe is 3 4 NPT on all models NPT to ISO adapter gas pressure regulator supplied with all models Natural Propane HEEGM24CE 4 17 0 61 2 15 2 54 9 HEEGM36CE 6 25 5 91 8 22 9 82 3 HEEGM48CE 9 38 2 137 7 34 3 123 4 HEEGM60CE 11 46 7 168 3 41 9 150 9 CE Approved Gas Categories Country Gas Category Gas Type Pressure mbar AT CH CZ DK ES FI GB GR IE IT NO PT SE LU I2H G20 20 DE I2E G...

Page 4: ... NPT GAS INLET NPT TO ISO ADAPTER SUPPLIED 28 925in 735mm LEG DEPTH 7 850in 199mm VALVE HEIGHT 1 3 RAIL DEPTH STUB RAIL DEPTH DIMENSIONS AND SPECIFICATIONS continued Dimensions Width Measurements Model Cook Width C Leg Pitch D Overall Width E Grease Tray HEEGM24CE 19 906in 506mm 14 124in 359mm 23 500in 597mm SINGLE HEEGM36CE 29 906in 760mm 24 124in 613mm 33 500in 851mm SINGLE HEEGM48CE 43 906in 11...

Page 5: ...designed specifically for holding warming fajita pans in lieu of two reversible or single sided grates N C Equipment Stands are available see HEMST specification sheet 10 foot 3 meters power cord with CEE7 7 plug head or BS1363 A plug head Standard and Optional Features PRE INSTALLATION INSTALLATION MAINTENANCE AND REPAIRS SHOULD BE DONE BY AN AUTHORIZED SERVICE AGENCY FOR A LIST OF AUTHORIZED SER...

Page 6: ...hims for countertop installation IT IS IMPERATIVE THAT THE UNIT IS PROPERLY LEVELED DURING INSTALLATION TO ENSURE OPTIMAL PERFORMANCE OF THE PRODUCT 3 For cleanliness the unit can be sealed to the mounting surface with silicone If sealing the unit to the surface avoid sealing lower stainless steel panels to the surface as these may need to be removed for service 4 Position the appliance in an area...

Page 7: ...her foreign matter will not clog pilots valves and or controls If necessary purge new piping prior to connecting the appliance Use pipe sealant that is certified for use with liquefied petroleum for new joints and or connections where sealant is required 3 Air movement should be checked during installation There must be adequate air intake into the building to compensate for the amount of air remo...

Page 8: ...unit is running at the pressure stated on the rating plate as follows FOR HEEGM24 36 SIZE UNITS Connect a manometer to the test spigot on the manifold Turn on the unit and adjust the burners so that they are all set to high If necessary adjust the pressure so that the reading on the manometer matches the pressure value stated on the rating plate To adjust the pressure access and rotate the pressur...

Page 9: ...ockout mode turn the power switch to the OFF position and remove power to the unit USE AND CARE Ignition can be attempted again by turning the power switch to the ON position and restoring power to the unit IMPORTANT Wait 5 minutes between ignition attempts If ignition fails again and the unit goes back into lockout turn the power off and have a qualified service technician inspect the unit 3 Mode...

Page 10: ...front rail grease tray handle and valve panel may get hot enough to burn skin Do not operate the broiler without the side shields in place as it may adversely affect the performance of the unit and or allow heat to migrate to neighboring equipment property causing damage The shields also prevent the cooking grates from sliding off the side of the unit when they are placed in the elevated position ...

Page 11: ...s on one appliance is prohibited and could void your warranty The fajita pan grate has been designed to accommodate only one fajita pan per slot in either the vertical or horizontal position as shown in the image below Placing multiple fajita pans in one slot and or placing fajita pans flat on this grate or the standard grate may cause damage to the broiler and could void your warranty THE FAJITA ...

Page 12: ...f grease debris The cooking grates on this unit are shielded from open flame by the radiants Attempting to burn off grease debris will likely have the opposite effect and cause the grease debris to stick even more When cleaning cast iron components such as the cooking grates radiants and burners do not handle these components roughly Dropping them on the floor or in the sink may cause them to crac...

Page 13: ...ean the side shields with a hot soapy solution and or a food safe liquid cleaner designed to clean stainless steel CLEANING AND MAINTENANCE continued 2 Remove the burners and hanging shields from the unit as follows Remove the pins at the rear of the burner Lift the burner peg up and out of the bracket at the rear Slide the burner back and off the orifice Angle the front of the burner down and the...

Page 14: ... requires service contact your local authorized Manitowoc service agency All repairs must be performed by a qualified technician using genuine Garland replacement parts or risk negating the warranty For a list of Authorized Service Agents or to view a Genuine Parts list for your appliance visit the Manitowoc Foodservice website at http www ManitowocFoodservice com Refer to the rating plate when ca...

Page 15: ...Part 4532435 Rev 02 Sep 9 14 Page 15 NOTES ...

Page 16: ...ation and Operation Manual GARLAND COMMERCIAL RANGES LTD 1177 Kamato Rd Mississauga ON L4W 1X4 Canada www Garland Group com MANITOWOC FOODSERVICE Sales and Service www ManitowocFoodservice com Part 4532435 Rev 02 09 09 14 2013 Garland Commercial Ranges Ltd ...

Reviews: