background image

Part # 4532435 Rev 02 (Sep 9/14)

Page 5

Standard Features

• 

All stainless steel construction.

• 

Front rail with cut outs to hold 1/3 size food pans (pans not included).

• 

Heavy duty reversible cast iron grates with wide edge on one side and fi ne edge on the other. Included: brush and 
scraper combination tool for cleaning grates.

• 

Two grate positions to choose from:  the standard position, with a slight 2° slope to the front or the second position, with 
a 10° slope to the front and more distance between the product and the burner.

• 

Large capacity, removable grease tray(s). HEEGM24CE & 36CE models have one tray and HEEGM48CE & 60CE have two 
trays.

• Energy 

effi

  cient cast iron burners.

• 

Complete system ON/OFF power switch(es), which ignites burners and shuts them down.  HEEGM24CE & 36CE models 
have one switch and HEEGM48CE & 60CE have two switches.

• Complete 

fl ame failure protection.

• 

Each burner outputs 14,500 BTU for natural gas & 13,000 BTU for propane gas, and is individually controlled by a manual 
high-low valve. Reference the "CE Approved Gas Category" table for applicable gas category, gas type and supply 
pressure.

• 

24" and 36" units are direct spark to the main burner. 48" and 60" units are direct spark to a pilot which then lights a pair 
of main burners.

• 

10-foot (3 meters) power cord with no plug head.

• 

¾” (19.1mm) gas regulator for applicable gas type, and NPT to ISO adapter supplied with all units.

Optional Features

• 

2-1/8" solid stub front rail, in lieu of standard 1/3 pan rail N/C

• 

Fajita pan grate designed specifi cally for holding/warming fajita pans, in lieu of two reversible or single sided grates N/C.

• 

Equipment Stands are available, see HEMST specifi cation sheet.

• 

10-foot (3 meters) power cord with CEE7/7 plug head or BS1363/A plug head.

Standard and Optional Features

PRE-INSTALLATION

INSTALLATION, MAINTENANCE AND REPAIRS SHOULD BE 
DONE BY AN AUTHORIZED SERVICE AGENCY.  FOR A LIST OF 
AUTHORIZED SERVICE AGENTS, REFER TO THE MANITOWOC 
WEBSITE AT www.ManitowocFoodservice.com

Introduction

Garland manufactures the HEEGM series broilers in several 
sizes.  While service and customer operation may vary 
from size to size, installation is similar for each.  All units are 
shipped fully assembled, except for the radiants and top 
grates, which are packaged in separate boxes.  Each unit 
is tested, adjusted and inspected at the factory prior to 
shipment.

Damage Check

After unpacking the unit, carefully inspect the unit for 
visible and concealed damage.  Report any damage 

immediately to your carrier to fi le the appropriate freight 

claims.

Rating Plate

The rating plate can be found on the inside face of the left 
leg.  If necessary, remove the grease drawer to read the 
information.  If service or replacement parts are needed, 
refer to the FULL model number (prefi x, suffi

  x, letters and 

numbers) AND serial number on the rating plate when 
contacting the factory or authorized service agency.  These 
numbers ensure proper unit identifi cation and aid in 
providing faster and accurate service.

The rating plate contains other important information 
critical to the proper installation of the unit.  It specifi es the 
gas type; gas pressure; voltage and clearance requirements 
for the appliance.

Summary of Contents for HEEGM24CE

Page 1: ... OTHER FLAMMABLE VAPORS OR LIQUIDS IN THE VICINITY OF THIS OR ANY OTHER APPLIANCE WARNING IMPROPER INSTALLATION ADJUSTMENT ALTERATION SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT PLEASE READ ALL SECTIONS OF THIS MANUAL AND RETAIN FOR FUTURE REFERENCE THIS PRODUC...

Page 2: ...5 Introduction 5 Damage Check 5 Rating Plate 5 INSTALLATION 6 General 6 Australia Specific Regulation 6 Positioning and Setup 6 Optional Stand 6 Air Supply and Ventilation 6 Electrical Connection 7 Gas Connection 7 Start Up 8 Operation 9 USE AND CARE 9 Warnings 10 Optional Equipment 11 CLEANING AND MAINTENANCE 12 General 12 Warnings 12 Cleaning During Operations 12 Daily Cleaning 13 Weekly Periodi...

Page 3: ...000 ft 610m Gas inlet pipe is 3 4 NPT on all models NPT to ISO adapter gas pressure regulator supplied with all models Natural Propane HEEGM24CE 4 17 0 61 2 15 2 54 9 HEEGM36CE 6 25 5 91 8 22 9 82 3 HEEGM48CE 9 38 2 137 7 34 3 123 4 HEEGM60CE 11 46 7 168 3 41 9 150 9 CE Approved Gas Categories Country Gas Category Gas Type Pressure mbar AT CH CZ DK ES FI GB GR IE IT NO PT SE LU I2H G20 20 DE I2E G...

Page 4: ... NPT GAS INLET NPT TO ISO ADAPTER SUPPLIED 28 925in 735mm LEG DEPTH 7 850in 199mm VALVE HEIGHT 1 3 RAIL DEPTH STUB RAIL DEPTH DIMENSIONS AND SPECIFICATIONS continued Dimensions Width Measurements Model Cook Width C Leg Pitch D Overall Width E Grease Tray HEEGM24CE 19 906in 506mm 14 124in 359mm 23 500in 597mm SINGLE HEEGM36CE 29 906in 760mm 24 124in 613mm 33 500in 851mm SINGLE HEEGM48CE 43 906in 11...

Page 5: ...designed specifically for holding warming fajita pans in lieu of two reversible or single sided grates N C Equipment Stands are available see HEMST specification sheet 10 foot 3 meters power cord with CEE7 7 plug head or BS1363 A plug head Standard and Optional Features PRE INSTALLATION INSTALLATION MAINTENANCE AND REPAIRS SHOULD BE DONE BY AN AUTHORIZED SERVICE AGENCY FOR A LIST OF AUTHORIZED SER...

Page 6: ...hims for countertop installation IT IS IMPERATIVE THAT THE UNIT IS PROPERLY LEVELED DURING INSTALLATION TO ENSURE OPTIMAL PERFORMANCE OF THE PRODUCT 3 For cleanliness the unit can be sealed to the mounting surface with silicone If sealing the unit to the surface avoid sealing lower stainless steel panels to the surface as these may need to be removed for service 4 Position the appliance in an area...

Page 7: ...her foreign matter will not clog pilots valves and or controls If necessary purge new piping prior to connecting the appliance Use pipe sealant that is certified for use with liquefied petroleum for new joints and or connections where sealant is required 3 Air movement should be checked during installation There must be adequate air intake into the building to compensate for the amount of air remo...

Page 8: ...unit is running at the pressure stated on the rating plate as follows FOR HEEGM24 36 SIZE UNITS Connect a manometer to the test spigot on the manifold Turn on the unit and adjust the burners so that they are all set to high If necessary adjust the pressure so that the reading on the manometer matches the pressure value stated on the rating plate To adjust the pressure access and rotate the pressur...

Page 9: ...ockout mode turn the power switch to the OFF position and remove power to the unit USE AND CARE Ignition can be attempted again by turning the power switch to the ON position and restoring power to the unit IMPORTANT Wait 5 minutes between ignition attempts If ignition fails again and the unit goes back into lockout turn the power off and have a qualified service technician inspect the unit 3 Mode...

Page 10: ...front rail grease tray handle and valve panel may get hot enough to burn skin Do not operate the broiler without the side shields in place as it may adversely affect the performance of the unit and or allow heat to migrate to neighboring equipment property causing damage The shields also prevent the cooking grates from sliding off the side of the unit when they are placed in the elevated position ...

Page 11: ...s on one appliance is prohibited and could void your warranty The fajita pan grate has been designed to accommodate only one fajita pan per slot in either the vertical or horizontal position as shown in the image below Placing multiple fajita pans in one slot and or placing fajita pans flat on this grate or the standard grate may cause damage to the broiler and could void your warranty THE FAJITA ...

Page 12: ...f grease debris The cooking grates on this unit are shielded from open flame by the radiants Attempting to burn off grease debris will likely have the opposite effect and cause the grease debris to stick even more When cleaning cast iron components such as the cooking grates radiants and burners do not handle these components roughly Dropping them on the floor or in the sink may cause them to crac...

Page 13: ...ean the side shields with a hot soapy solution and or a food safe liquid cleaner designed to clean stainless steel CLEANING AND MAINTENANCE continued 2 Remove the burners and hanging shields from the unit as follows Remove the pins at the rear of the burner Lift the burner peg up and out of the bracket at the rear Slide the burner back and off the orifice Angle the front of the burner down and the...

Page 14: ... requires service contact your local authorized Manitowoc service agency All repairs must be performed by a qualified technician using genuine Garland replacement parts or risk negating the warranty For a list of Authorized Service Agents or to view a Genuine Parts list for your appliance visit the Manitowoc Foodservice website at http www ManitowocFoodservice com Refer to the rating plate when ca...

Page 15: ...Part 4532435 Rev 02 Sep 9 14 Page 15 NOTES ...

Page 16: ...ation and Operation Manual GARLAND COMMERCIAL RANGES LTD 1177 Kamato Rd Mississauga ON L4W 1X4 Canada www Garland Group com MANITOWOC FOODSERVICE Sales and Service www ManitowocFoodservice com Part 4532435 Rev 02 09 09 14 2013 Garland Commercial Ranges Ltd ...