Installation
RTCSmp Built-In Module-Line Dual/Quad Cooktops
16
Part # 4532415 Rev 1 (12/12/13)
4.3
Control Unit and Operation Unit/Power Switches
4.3.1
Location
•
Distance of the control unit from the coil carrier sheet: MAX. 31.50” / 80cm.
•
Distance of the control unit from the operation unit (power switch): MAX. 31.50” / 80cm.
•
Ensure the Service Interface window of the control unit (see
4.3.4 Dimensions—Control Unit
) is not
blocked and is easily accessible for service.
•
Ensure the cable connections are accessible for service.
4.3.2
Ventilation
•
The control and operation units can be installed around heat-producing equipment such as an oven, if
and only if the ambient temperature is below 104
°
F (40
°
C). An external fan must be used to remove the
air away from the control unit.
•
Prevent moisture, hot or greasy ambient air being drawn into the installation compartment. Pay
attention to the ventilation when the induction unit is installed next to other induction units, appliances,
or fryers and ovens.
4.3.3
Mounting Methods
•
Mount the control unit with the installation brackets provided. See “Mounting Version” in section
4.24
Dimensions – Control Unit
.
o
Mount the control unit directly onto the cabinet compartment wall/shelf, or
o
Stud-mount the control unit onto the back of the control panel. Use the dimensions provided in
section
4.2.5 Dimensions Guide
as a guide for installing the control unit, the operation units
(power switches) and the LED Indicator lights.
•
Use two (2) M4 screws to secure the operation units (power switches) onto the control panel. See section
4.2.5 Dimensions Guide
.
4.3.4
Dimensions – Control Unit