Installation
RTCSmp Built-In Module-Line Dual/Quad Cooktops
14
Part # 4532415 Rev 1 (12/12/13)
The call-outs in the illustrations show:
(
C
) Hot air exhaust from the generator.
(
D
) Air intake through the air intake opening on the generator.
(
E
) Louvered air exhaust opening installed on the cabinet.
(
F
) Control Unit mounted to the underside of the countertop.
(
G
) Mounting frame.
(
H
) Coil Carrier Sheet inserted into the Mounting Frame.
(
I
)
CLEARANCE
: minimum 10cm / 3.94”. See section
4.3 Coil Carrier Sheet, Ceran Glass and Mounting
Frame
.
(
J
) Ensure the distance between the control unit and the coil carrier sheet is
less than 80cm/31.5”
.
4.2
Induction Generator
4.2.1
Location
•
The induction generator can be installed around heat-producing equipment such as an oven, if and only
if the ambient temperature is below 104
°
F (40
°
C). An external fan must be used to remove the air away
from the induction unit. NOTE: Additional fans and cooling controls are the responsibility of the installer.
•
Prevent moisture, hot ambient air or greasy fume being drawn in by the induction generator, especially
when the equipment is side-by-side or in the vicinity of a fryer or oven.
•
Keep all the combustible materials, vapors or liquids away from the generator.
•
Ensure the installed location of the generator is safe from any ingress of liquid into the immediate
vicinity.
•
Ensure the cable connections are accessible for service.
4.2.2
Ventilation
Proper cool air intake and ventilation is essential to the reliability and functioning of the induction unit. Please
ensure all requirements listed below are met:
•
The induction generator has an air intake and an air exhaust openings. Ensure these openings are not
blocked.
Clearance
from obstructions: minimum 1.57”(40mm) for the air intake and exhaust openings;
minimum 0.39”(10mm) for the sides.
•
The air intake temperature must not exceed 104
°
F (40
°
C). If the generator is installed directly under the
coil or in the same chamber of the cabinet as the coil, ensure the ventilation system will keep the
ambient temperature for operation below 104
°
F (40
°
C).
•
Maximum air flow of the fan is 70.63 cfm (120 m
3
per hour) and therefore a minimum opening of 10.08
sq. in. (6500 mm
2
) is required around the fresh air inlet.
•
An optimal air circulation and air flow must not be restricted by the installation.
•
When installing the units, ensure the intake air and exhaust air are conducted separately. The in-take air
and exhaust air must not mix. To avoid build-up of hot exhaust air inside the counter, draw the exhaust
air out of the counter, or provide a separate exhaust air plenum. Build up of hot exhaust air will cause the
induction unit to reduce power or to switch-off.
•
Ensure the induction unit does not take in hot ambient air from other surrounding units and appliances,
especially when the installed location of the unit is close to heat generating equipment such as a fryer or
an oven.