23
will report to the Monitoring Center, and
the GREEN LED slowly flashes.
z
If Low Battery condition persists, IC2020
will emit 2 short beeps every hour.
z
Press
the
NURSE
button to clear the
warning beeps, and the LED returns to
steady ON.
z
After the battery voltage is restored and
lasts for 12 hours, IC2020 will send
Battery Restore
report to Monitoring
Center and the GREEN LED returns to
steady ON.
4.1.5. Devices Low Battery
z
Whenever IC2020 receives a battery low
signal from a particular device, it will report
to the Monitoring Center each time a low
battery signal is received, and the GREEN
LED will flash rapidly until the fault
condition is cleared.
z
In addition, IC2020 will emit 4 short beeps
every hour. Press the
NURSE
button on
IC2020 will stop the warning beeps.
<
<
N
N
O
O
T
T
E
E
>
>
)
If any device Low Battery signal is
received again, the LED and warning
beeps will be performed accordingly.
Press the
NURSE
button again to silent
the warning beeps.
z
Portable devices such as Wrist
Transmitter and Panic Button must reside
in the RF range for the Control Panel to
receive the low battery signal and then
report to the Monitoring Center.
z
If line failure is detected and the device
low battery reporting has been previously
made before the line failure period, then
no more device low battery reporting will
be made after the line failure is restored.
However, if the device low battery
condition is first detected during the line
failure period, then a device low battery
reporting will be made after the line failure
is restored.
z
After the faulty battery is replaced, IC2020
will immediately send
Battery Restore
report to the Monitoring Center for that
particular device.
4.1.6. Automatic Check-in Report =
Periodic Test Call
z
When IC2020 is programmed to send a
periodical check-in report, IC2020 will
report to the Monitoring Center accordingly.
z
The Periodic-Check-in Timer will be reset
whenever the Programming Mode is
entered.
4.1.7. Mobility Timer
z
In order to check the user’s well being, a
Mobility Timer can be set by using
Command #44.
z
If Mobility Timer is set as
Enable
, a
counting down period starts from:
Immediately after powering up
IC2020
Exit
Programming
Mode
z
After the pre-set Timer expires, IC2020 will
emit a beep at every 5 minutes to notify
the user for 30 minutes.
z
When the Mobility timer is not reset after
30 minutes, IC2020 will send a
Mobility
Timer Expired
report to the Monitoring
Center every 30 min until timer is reset.
z
Mobility Timer can be reset by pressing
NURSE
button once on IC2020 or
whenever a movement is detected by PIR
Detector.
z
To disable the Mobility Timer function:
Set Command #44 to
0
(Disable)
<
<
N
N
O
O
T
T
E
E
>
>
)
Please use Command #44 to enable the
Mobility timer again.
4.1.8. No Pendant Present
z
This function is only available for the
digital Contact ID reporting method.
z
If there is no pendent being learnt into
IC2020 30 min after powering up, it will
send a
No Pendant Learnt-in
report to
the Monitoring Center and repeat every
hour thereafter, until a pendant is
successfully learnt in.