18
z
Once the playback is finished, two beeps
will be heard as an indication.
<
<
N
N
O
O
T
T
E
E
>
>
)
Message can only be heard locally
alongside IC2020 via the bulilt-in
Speaker.
Command 52
Panic Mode Enable
z
The IC2020 can be programmed to enable
Panic Mode or not.
z
When set as
ON
, Panic Alarm can be
activated/deactivated via the Remote
(IC2020TX).
z
To activate Panic Alarm: Press and hold the
White NURSE button for 5 sec. The
NURSE button will light up steadily in Blue
for 1 sec. The Control Panel will repeatedly
play “
Beep Beep Beep Emergency
” until
Panic Alarm is deactivated.
z
To deactivate Panic Alarm: Press and hold
the White NURSE button for 5 sec again.
The NURSE button will light up steadily in
Blue for 1 sec.
Function Selection
Result
(0)
OFF
(Disable)
(1)
ON
(Enable)
z
Factory Default
is
set as (
0
),
OFF
.
<
<
N
N
O
O
T
T
E
E
>
>
)
Panic Alarm can only be triggered via
the Remote (IC2020TX), and only
when Panic Mode Enable is set as
ON
.
Command 53
Line Failure Detection Voice Message
z
This option is used to set the repeating
cycle of the voice prompt “
Phone line
trouble
” when telephone line failure is
detected.
z
If set as 1 minute, then the voice prompt
will repeat every 1 minute, and so on.
Function Selection
Result
(00)
Disable
(No repeat)
(01) 1
minute
(02) 2
minutes
(03)-(60)
3-60 minutes
z
Factory Default
is
set as (
00
), No repeat.
<
<
N
N
O
O
T
T
E
E
>
>
)
During the line failure period, the voice
prompt “
Phone line trouble
” will be
played by the set repeating cycle, but
the red LED will still flash quickly until
the line failure is restored.
)
During the line failure period, if the
Emergency or Nurse button is pressed
or any sensor is triggered, the red LED
will flash quickly and the voice prompt
“
Phone line trouble
” will be played
(even if set as
00
,
Disable
). The
reporting will then be made after the
line failure is restored.
)
During the reporting period after line
failure restore (if the Emergency or
Nurse button is pressed or any sensor
is triggered during the line failure
period), line failure detection will be
temporarily stopped.
)
Line failure and restore will not be
reported.
)
At least one telephone and account #
must exist in order for line failure
detection to start. Line failure detection
will not start if no telephone nor
account # exist (even after powered on
for one minute).
Command 54
Nurse Call Out Period
z
This command is used to program the
allowable time duration for
Nurse Call
mode in Two-way voice communication
period (Speech mode). It can be set from
(
01
) (1 minute) - (
60
) (60 minutes).