14
Command 38
Follow-On & Call-Back Function
z
The Command is available for Digital
Reporting Methods (when Command #20 -
#24 is set as (0), (1) or (2))
Function Selection
Result
(0) Follow-On
(1) Call-Back
(2)
Follow-On & Call-Back
z
Factory Default
is set
as
(
0
)
, Follow-On
.
z
When this function is programmed as (
0
),
after a successful reporting to the
Monitoring Center, IC2020 will
automatically enter the specific Follow-On
mode as specified by Command (
45
).
z
When this function is programmed as (
1
),
after a successful reporting to the
Monitoring Center, IC2020 will
automatically hang up the line and start a
5-minute waiting period to auto answer any
incoming phone calls from the Monitoring
Center.
z
When this function is programmed as (
2
),
after a successful reporting to the
Monitoring Center, the IC2020 will
automatically enter specific Follow-On
mode as specified by Command (
45
).
Once Follow-On Mode is terminated,
IC2020 will automatically start a 5-minute
waiting period to auto answer any incoming
phone calls from the Monitoring Center.
<
<
N
N
O
O
T
T
E
E
>
>
)
When the Monitoring Center calls
back within this 5-minute period,
IC2020 auto-answers the call after the
1st -2nd ring and waits for proper
Access Code (default is (
1111
)) entry
followed by the (
#
) key within 15 sec.
Upon the correct Access Code
received, IC2020 will then open a
Full-Duplex Communication to allow
the Call Recipient to speak to IC2020
directly.
)
The first digit of Access Code must be
entered within 15 secs, otherwise,
IC2020 will disconnect the call
automatically.
)
Failure to enter the correct Access
Code within 2 mins will cause IC2020
to automatically disconnect the call.
)
To terminate the call, press DTMF (
9
)
or NURSE BUTTON on IC2020.
)
If the 5-minute waiting period is up,
IC2020 will automatically exit this
waiting mode and return to idle mode.
)
Command #41 (Auto Answer for
Remote Programming) will not be able
to proceed during the 5-mins Call-
back time.
Command 39
Dialing Mode
z
This function is for you to select the dialing
method of your telecommunications.
z
There are two dialing methods available for
user:
Function Selection
Result
(0) TONE
(1) PULSE
z
Factory Default is set as (
0
),
TONE
.
Command 40
Set Access Code
z
The Access Code is used to enter
Programming Menu (locally or remotely),
and the Call-Back Function.
z
It consists of 4 digits and has been set to
(
1111
) as factory default. Before you set
your own Access Code,
(
1111
) must be
keyed in.
z
To set a new Access code; enter the
desired (
4-digit number
) in
Function
Selection
.