background image

12

Welch-Ilmvac

5621 W. Howard Street

Niles, IL 60714

Phone: (847) 676-8800 (Technical Support)

Fax: (847) 677-8606

E-Mail: [email protected]

Web-Page: www.welchvacuum.com

Copyright© 2007 Gardner Denver Thomas Inc., Welch Vacuum Technology

Welch is a registered trademark of Gardner Denver Thomas Inc., Welch Vacuum Technology

USA, Canada, Latin America
Gardner Denver Thomas, Inc.,
Welch Vacuum Technology
5621 W. Howard St.
Niles, IL  60714   USA
Phone: 847-676-8800
Fax: 847-677-8606
Email: [email protected]

Asia

Rietschle Thomas Asia Pacifi c, Ltd.

Unit 2503, Metropole Square
No. 2 On Yiu St., Siu Lek Yuen
Shatin, New Territories, Hong Kong, P.R.C.
Phone: 852 2690 3502
Fax: 852 2792 4598
Email: 

[email protected]

Europe
Gardner Denver UK
Waterbrook Estate, Waterbrook Road
Alton Hampshire
GU342UD United Kingdom
Phone: 01 420 544 184
Fax: 01 420 544 183
Email: 

[email protected]

SALES AND SERVICE OFFICES

Summary of Contents for WELCH GEMINI 2050

Page 1: ...mited by compatibility with pump materials of construction Always verify vapor chemical compatibility prior to pump use and utilize proper cleaning methods to remove chemical residuals from the pump a...

Page 2: ...ction could result in injury or death to people CAUTION Cautions are found where failure to observe the instruction could result in damage to the equipment associated equipment and process These units...

Page 3: ...02 INSTALLATION 2 10 Introduction 2 20 Unpacking 2 30 Pump Location 2 40 Application Connection Section 03 OPERATION 3 10 Starting Procedures Applications Quali cation 3 20 Leak Detection 3 30 Pump Cl...

Page 4: ...part of the body 1 18 Use only in well ventilated areas 1 19 Never block pump exhaust Serious injury can result from pressure build up 1 20 To Reduce Risk Of Electrical Shock 1 21 Do not disassemble...

Page 5: ...urrounding temperature remains between 10 C and 40 C 50 F and 104 F Always check to insure the location chosen is protected from direct or indirect moisture contact 2 32 Electrical Source GEMINI pumps...

Page 6: ...port Pressure build up in the pump will cause pump to stall 2 42 Tubing Connection Use non collapsible tubing for all vacuum connections Connect to pump inlet using 3 8 10mm ID tubing keeping tubing...

Page 7: ...ons as well as certain alcohols ethanol isopropanol and carboxylic acids acetic acid It is important to check for pump material compatibility with potential fumes that can be drawn off your vacuum app...

Page 8: ...mBar GEMINI Start Up After verifying that your vacuum application is correctly con gured per Section 2 Installation turn on the pump On Off switch Welch recommends running the pump for a few minutes...

Page 9: ...r vapors through the pump for 5 minutes to clean pump contact surfaces GEMINI System Shutdown Procedures After use Welch recommends the pump be run for about 2 minutes disconnected from the vacuum pro...

Page 10: ...ower Failure If pump does not turn on the power adapter can be replaced Contact your Welch representative for information 10 SECTION 6 SPECIFICATION 6 10 SPECIFICATION TABLE 5 10 5 11 5 20 5 21 Parame...

Page 11: ...for any period however short will be repaired under this warranty rather than replaced The warranty is effective for one year from the date of original purchase when 1 The warranty card has been comp...

Page 12: ...ca Gardner Denver Thomas Inc Welch Vacuum Technology 5621 W Howard St Niles IL 60714 USA Phone 847 676 8800 Fax 847 677 8606 Email gdwelchvacuum gardnerdenver com Asia Rietschle Thomas Asia Paci c Ltd...

Reviews: