TROUBLESHOOTING 

Sec  Symptom 

  Possible Cause(s) 

Corrective Action 

Water downstream of 
dryer. 

1.  Residual free moisture 

remaining in downstream 
piping 

Drain low spots in system and purge with dry 
air 

 

 

2.  Air By-pass system is 

open 

Verify valve positions and correct valve 
positions 

 

 

3.  Ambient temperature 

surrounding downstream 
piping is below the dryer’s 
dewpoint. 

Insulate and/or heat trace piping exposed to 
low ambient temperatures or dry air to a lower 
dewpoint. 

 

 

4.  Free water (liquid) is 

entering the dryer 

Dryers are designed to handle saturated air 
not condensed liquid. Install a separator and 
coalescing filter upstream of dryer. 

 

 

5.  Condensate is not being 

drained  

See section B 

 

 

6.  Dryer is overloaded 

resulting in high dewpoint 

See capacity charts to determine correct load 

 

 

7.  Refrigeration system is not 

functioning. 

See section E 

 

 

8.  Suction pressure not in 

operating range 

Contact your local distributor to perform 
adjustments. 

Drain System Failure 
with no condensate 
discharge on test 
initiation. 

1.  Drain strainer is clogged 

Depressurize dryer and replace or clean drain 
strainer. 

2.  Solenoid valve or 

electronic timer failure 

Replace drain solenoid and or timer assembly 

Drain System Failure 
with continuous 
condensate or air 
discharge. 

1.  Solenoid valve diaphragm 

rupture or orifice path 
blocked open 

Clean or replace internal diaphragm 
assembly. 

High pressure drop 
across dryer 

1.  Inlet flow exceeds 

maximum capacity 

Check inlet flow vs. rated capacity 

2.  Freezing of moisture in 

evaporator is restricting 
inlet air flow 

If refrigerant suction pressure is out of 
standard operating range, contact your local 
distributor to perform adjustments. 

Refrigeration System Fault 

E1 

Power on indicator 
does not illuminate 

1.  Power failure, Line fuses 

blown, or disconnect 
open. 

Have an electrician check electrical feed and 
connection integrity. 

E2 

Refrigeration 
compressor cycles on 
and off 

1.  Ambient Conditions are 

above or below minimum 
or maximum ranges.   

Verify range and rectify ambient 
conditions. 

 

 

2.  Air-Cooled Units, 

Dirty condenser  

Clean condenser as per required 
maintenance.  

 

 

3.  Water-Cooled Units, 

High fluid temperature or 
low fluid flow. 

Check fluid temperature, bring in 
range and check for free fluid flow 
through condenser.  If problem 
persists contact your local distributor 
to perform adjustments. 

 
 

 

Summary of Contents for GSRN Series

Page 1: ...NG STANDARD Contents Introduction Page 2 General Safety Warnings Page 2 Proper Use of the Dryer Page 3 Receiving Equipment Page 3 Installation Location and Piping Page 3 Recommended System Design Page...

Page 2: ...00 682 9868 Failure to install the compressed air dryer per this manual or any change to the dryer not previously authorized by the manufacture will void the warranty The information and specification...

Page 3: ...be located on a level floor or shelf free from vibrations and sufficient to support the total weight of the machinery Although the dryer package is a freestanding unit it may be secured by bolting th...

Page 4: ...100 F 37 7 C 105 F 40 5 C 110 F 43 3 C 115 F 46 1 C 120 F 48 8 C Additional Load 0 15 32 51 75 The pipe connection to the dryer should match the standard connection ports provided The chart below is p...

Page 5: ...ssembly GSRN 50 through GSRN 2250 When maintaining float drains depressurize the dryer drain prior to work initiation Drain line and Drain Connector must be removed prior to bowl and float drain remov...

Page 6: ...0 PSIG for two fan units If the suction analyzer or discharge gauge is not in the specified range contact your local distributor GSRN 100W through GSRN 200W The water cooled series GSRN 100W through G...

Page 7: ...y discharging condensate and air from the drain tube try replacing the solenoid valve diaphragm or the complete drain valve As Required MODEL CAPACITY CORRECTION MULTIPLIER Inlet Temp 90 F 100 F 110 F...

Page 8: ...rize dryer and replace or clean drain strainer 2 Solenoid valve or electronic timer failure Replace drain solenoid and or timer assembly C Drain System Failure with continuous condensate or air discha...

Page 9: ...1200 1500 1750 2000 2250 Min Max Inlet Pressure 30 PSIG 2 1 kgf cm 220 PSIG 30 PSIG 2 1 kgf cm 150 PSIG 10 6 kgf cm Max Inlet Temperature 120 F 48 8 C Min Max Ambient Temperature 50 F 10 C 110 F 43 3...

Page 10: ...to investigate and inspect any assumed defects At seller s option buyer must return any defective materials to seller s plant or authorized depot at buyer s expense Freight charges for returned or rep...

Reviews: