background image

23776 GB/2021-06

valid for: 
Air circulation dryers UT 16, UT 40, UT 75

3 4

Air Circulation Dryer UT

Operating Manual

Translation of Operating Manual 

Summary of Contents for SONOREX TECHNIK UT16

Page 1: ...23776 GB 2021 06 valid for Air circulation dryers UT 16 UT 40 UT 75 3 4 Air Circulation Dryer UT Operating Manual Translation of Operating Manual ...

Page 2: ...iginal version will take precedence BANDELIN accepts no responsibility or liability for damage caused by improper handling or usage contrary to the intended purpose The documentation has been prepared with great care All liability is excluded for any direct or indirect losses resulting from incomplete or erroneous information contained in this documentation or in its presentation or usage Subject ...

Page 3: ...and safety instructions chapter 1 at all times while using the device The manufacturer will not assume any responsibility for the device s safety or functional ability in the event of improper handling or usage contrary to the intended purpose Unauthorised alterations modifications will render both the warranty claim and the CE conformity null and void If service is required please contact the aut...

Page 4: ...ription 8 2 1 Mode of operation 9 2 2 Intended purpose 9 2 3 CE conformity 9 2 4 Technical data general 10 3 Preparation 12 3 1 Scope of delivery 12 3 2 Setup assembly 12 3 3 Commissioning 13 4 Operation 13 4 1 Operating elements 13 5 Application 14 5 1 Instructions for use 14 5 2 General use 14 6 Maintenance and cleaning 15 6 1 Cleaning and care 15 6 2 Warehousing storage 15 ...

Page 5: ...3 4 12207 Berlin Deutschland info bandelin com 7 Service and repair 16 7 1 Service 16 7 2 Troubleshooting 16 7 3 Customer service 17 7 3 1 Repairs and service 17 7 3 2 Certificate of Decontamination 17 8 Decommissioning 18 System Original operating manual blower ...

Page 6: ...ponents may only be performed by authorised personnel Protect yourself with suitable personal protective equipment protective gloves Inspect the thermal components in accordance with the service schedule Switch on the device only if the inspection of the thermal components shows no defects Inform your supervisor if the inspection of the thermal components reveals any defects Hazards due to noise e...

Page 7: ...only the connection materials supplied If the air circulation dryer changes ownership the operating manual and safety instructions must also be passed on to the new owner Operation and transport Place the air circulation dryer upright on a dry and solid foundation Pay attention to the ambient conditions chapter 2 4 The remaining liquid may not contain any solvents that could produce an explosive a...

Page 8: ...ification and serial number are found on the identification plate on the back Product features Stainless steel tank 1 Stainless steel housing 2 Handles 3 Outlet 4 for hose socket Feet 5 for secure positioning Timer 6 for 1 15 min and continuous operation Heating 7 from 45 to 140 C Floor drain 8 for drainage of dripping water Incoming air openings 9 Intake opening 10 SONOREX TECHNIK UT 40 9 10 8 2 ...

Page 9: ...set through the controllers on the front If the basket cannot be used the shelf can be used as an option The shelf is placed on the dryer s tank bottom The dried items are then placed directly on the shelf 2 2 Intended purpose The device is designed to remove aqueous residual liquid from objects made of solid non flammable materials The parts to be dried must be placed in a basket provided for thi...

Page 10: ...e type plate on rear of device Degree of protection IP 21 pursuant to DIN EN 60529 Protected against access to dangerous parts with fingers Protected against solid foreign bodies with a diameter of 12 mm or larger Protected from dripping water Type UT 16 UT 40 UT 75 External dimensions L W H mm 365 480 390 540 480 495 640 640 550 Internal dimensions L W D mm 325 300 195 500 300 295 600 500 295 Out...

Page 11: ... 31 C 65 Permissible relative humidity to 40 C 65 Permissible air pressure 800 to 1050 mbar No dewing For indoor operation only Electromagnetic compatibility EMC The device has been tested for electromagnetic compatibility EMC and meets the requirements for Class B devices in accordance with EN 55011 It is suitable for use in institutions and other areas that are directly connected to a public low...

Page 12: ...te 3 2 Setup assembly Installation must be performed on solid ground The installation surface should be level and horizontal When setting the device up on the tank rack make sure that the device feet are positioned in the designated footprints in the process Pay attention to the maximum weight including items to be dried For net weight see the technical data chapter 2 4 Do not obstruct the air sup...

Page 13: ...rning knob 1 for heating The desired duration can be set with the turning knob 2 for the time preselection Notes The heating is only released when the fan is switched on simultaneously via the time preselection This is also a safety circuit the heating remains cold without the fan When switched off the air circulation dryer can remain connected to the mains It can be disconnected by pulling the mai...

Page 14: ...the side The fan compartment below the dryer tank also has an outlet After loading the device with the items to be dried the operator sets the desired temperature and duration The drying process starts when the process time is set 5 2 General use Step 1 Preparation Check that the hose at the outlet is not kinked on its way to the drain If the hose is kinked the liquid cannot drain Place the items ...

Page 15: ...G To achieve an optimum lifespan for the air circulation dryer cleaning and maintenance should be conducted regularly To do so allow the device to cool sufficiently CAUTION Disconnect the air circulation dryer from the mains before each cleaning maintenance Do not hose down and do not expose to splash water 6 1 Cleaning and care Do not use abrasive cleaners only use commercially available care produ...

Page 16: ...orised qualified personnel Unauthorised repairs will void the warranty Seq No Malfunction Possible cause s measure 1 Air circulation dryer does not heat up or does not become truly hot One or more heating elements have malfunctioned Setting of the thermostat is defective target temperature above actual temperature Timer defective Heating defective Air circulation dryer too hot Allow to cool 2 Blow...

Page 17: ...ervice E mail Tel 49 30 768 80 13 info bandelin com Fax 49 30 768 802 00 13 In the event of returns the General Terms and Conditions for Delivery and Payment of BANDELIN electronic GmbH Co KG apply In addition the air circulation dryer must be cleaned and decontaminated if necessary see the following chapter 7 3 2 Certificate of Decontamination If the air circulation dryer is returned to the manuf...

Page 18: ...e disposal It can then be disposed of as electronic waste If decontamination is incomplete cannot be correctly performed a material safety data sheet noting the liquids used must be affixed to each device Metal accessories such as the lid or basket should be decontaminated and disposed of as metal waste The packaging is recyclable BANDELIN electronic GmbH Co KG Heinrichstraße 3 4 12207 Berlin Deutsc...