INTRODUCTION 

 

Before attempting any installation or maintenance on the dryer, please 
carefully read this entire manual. 

Gardner  Denver®  Compressor  and  Dryer  genuine  parts,  manufactured  to  design  tolerances,  are 
developed for optimum dependability 

– specifically for Gardner Denver compressor and dryer systems. 

Design  and  material  innovations  are  the  result  of  years  of  experience  with  hundreds  of  different 
compressor and dryer applications. Reliability in materials and quality assurance are incorporated in our 
genuine replacement parts. 
 
Your authorized Gardner Denver Compressor and Dryer distributor offers all the backup and reassurance 
you’ll  need.   Our  network  of  authorized  distributors  provides  the  finest  product  support  in  the  air 
compressor industry. 
 
Your authorized distributor can support your Gardner Denver Dryer with these services: 

1.    Trained parts specialists to assist you in selecting the correct replacement parts. 
2.    Repair and maintenance kits designed with the necessary parts to simplify servicing 

 your dryer. 

3.    Authorized distributor service technicians are factory trained and skilled in compressor and dryer 

maintenance and repair. They are ready to respond and assist you by providing fast, expert 
maintenance and repair services. 

 
To Contact Gardner Denver or locate your local distributor: 
Visit: www.contactgd.com/compressors   or   
Call: (800) 682-9868 
 
Failure  to  install  the  compressed  air  dryer  per  this  manual  or  any  change  to  the  dryer  not  previously 
authorized by the manufacture will void the warranty.  
 
The information and specifications in this manual are in accordance with the information in effect at the 
time of printing. The manufacturer reserves the right to make changes without notice or incurring obligation. 
 

GENERAL SAFETY INFORMATION 

 

General Warning  

The associated text outlines conditions, which could indicate a hazardous situation that 
has some probability of death or severe injury. 

 

Electrical Hazard 

The associated text outlines conditions, which could indicate a hazardous situation that 
has some probability of death or severe injury.  
Only  qualified  personnel  can  use  and  service  electrically  powered  devices.  Be  sure 
that the voltage is disconnected before any work is performed. 
 

 

Personnel or Equipment Danger Hazard   

A compressed air dryer has two separate pressurized systems each with the 
potential to be pressurized independently. First is the sealed refrigeration system 
which should never be opened except by a licensed technician. Second is the actual 
compressed air circuit. Depressurize the compressed system prior to performing any 
work or maintenance on that system. Compressed air is a highly hazardous energy 
source. Never work on equipment with parts under pressure. 

 

Breathing Air 

Air treated by this equipment may not be suitable for breathing without further 
purification. Refer to applicable standards and specifications for the requirements of 
breathing quality air. 

 

PROPER USE OF DRYER 

Summary of Contents for GSRN Series

Page 1: ...NG STANDARD Contents Introduction Page 2 General Safety Warnings Page 2 Proper Use of the Dryer Page 3 Receiving Equipment Page 3 Installation Location and Piping Page 3 Recommended System Design Page...

Page 2: ...00 682 9868 Failure to install the compressed air dryer per this manual or any change to the dryer not previously authorized by the manufacture will void the warranty The information and specification...

Page 3: ...be located on a level floor or shelf free from vibrations and sufficient to support the total weight of the machinery Although the dryer package is a freestanding unit it may be secured by bolting th...

Page 4: ...100 F 37 7 C 105 F 40 5 C 110 F 43 3 C 115 F 46 1 C 120 F 48 8 C Additional Load 0 15 32 51 75 The pipe connection to the dryer should match the standard connection ports provided The chart below is p...

Page 5: ...ssembly GSRN 50 through GSRN 2250 When maintaining float drains depressurize the dryer drain prior to work initiation Drain line and Drain Connector must be removed prior to bowl and float drain remov...

Page 6: ...0 PSIG for two fan units If the suction analyzer or discharge gauge is not in the specified range contact your local distributor GSRN 100W through GSRN 200W The water cooled series GSRN 100W through G...

Page 7: ...y discharging condensate and air from the drain tube try replacing the solenoid valve diaphragm or the complete drain valve As Required MODEL CAPACITY CORRECTION MULTIPLIER Inlet Temp 90 F 100 F 110 F...

Page 8: ...rize dryer and replace or clean drain strainer 2 Solenoid valve or electronic timer failure Replace drain solenoid and or timer assembly C Drain System Failure with continuous condensate or air discha...

Page 9: ...1200 1500 1750 2000 2250 Min Max Inlet Pressure 30 PSIG 2 1 kgf cm 220 PSIG 30 PSIG 2 1 kgf cm 150 PSIG 10 6 kgf cm Max Inlet Temperature 120 F 48 8 C Min Max Ambient Temperature 50 F 10 C 110 F 43 3...

Page 10: ...to investigate and inspect any assumed defects At seller s option buyer must return any defective materials to seller s plant or authorized depot at buyer s expense Freight charges for returned or rep...