13-21-611 Page 37
4-6
Figure 4-4 -Turn Valve - Electra Saver Only
Turn Valve
(Electra-Saver only) (Figure 4-4)- The turn valve is a helical valve which, when rotated, opens
and closes a series of ports cast into the compressor cylinder. When these ports are open, they direct
some of the air which would otherwise be compressed back to the inlet, reducing both capacity and
power consumption.
Turn Valve Actuator
(Electra-Saver only) - The turn valve actuator is a rotary rack and pinion device
which positions the turn valve according to system demand. Filtered oil from the compressor sump is
directed to the outboard end of the two actuating cylinders to move the rack and rotate the valve.
Located on the ends of the cylinders are adjusting screws which limit the travel of the actuator. When
looking at the rear of the compressor, the adjusting screw on the right on the compressor adjusts the fully
closed (full-load) position of the valve. The full load position of the actuator may be checked by removing
the adjusting screw at the unloaded end of the actuator (left side of the compressor) and using a rod to
push the pistons to the full load position. The rod must be clean and free of burrs and scale. Take care
not to scrape the cylinder walls when moving the pistons.
Solenoid Valves TVC and TVO
(Electra-Saver only) - These valves control the position of the turn valve
in response to signals from the “AirSmart” controller. With both valves de-energized, equal pressure is
applied to both ends of the actuator to hold it in its present position. If TVC only is energized, the right
side of the turn valve actuator is exhausted to the compressor inlet cavity, causing the turn valve to move
towards the full load position. If TVO only is energized, the left end of the turn valve actuator is
exhausted to the compressor inlet cavity, causing the turn valve to move towards the unload position.
See “AirSmart” Controller Manual, for a description of how the turn valve position is controlled during
normal operation.
Plant Delivery (System) Pressure Transducer
- This transducer is connected after the aftercooler. It
converts the pressure in the plant air system into an electrical signal for use by the AirSmart G2 controller
for modulation and control.
Separator (Discharge) Pressure Transducer
- This transducer is connected after the minimum pressure
valve. Its signal is used to monitor the condition of the air/oil separator and cooler.
Reservoir Pressure Transducer
- This transducer is connected to the coolant system. Its signal is used
to prevent loaded starts, monitor reservoir pressure, and monitor the condition of the air/oil separator.
Air Filter
- This switch is used to monitor air filter condition and alert the user if the filter requires service or
replacement.
Summary of Contents for ELECTRA-SAVER G2
Page 12: ...13 21 611 Page 11 1 4 Figure 1 6 AIR OIL FLOW DIAGRAM 307EBD797 B Ref Drawing...
Page 41: ...4 10 THIS PAGE INTENTIONALLY LEFT BLANK 13 21 611 Page 40...
Page 42: ...4 10 FIGURE 4 6 COMPRESSOR PACKAGE P ID 13 21 611 Page 41 300EBF797 02 Ref Drawing...
Page 70: ...13 21 611 Page 69 5 4 Figure 5 3 FLOW DIAGRAM AIR OIL SYSTEM 300EBF797 02 Ref Drawing...
Page 74: ...13 21 611 Page 73 5 8 THIS PAGE INTENTIONALLY LEFT BLANK...