37-1-615 Page 45
NOTE:
It is recommended to apply a thin coat of Dow Corning 736 sealant on each side of gaskets
(58, 24) prior to installation.
The third important measurement for clearance is to provide for floating bearings at the gear
end.
22. Turn the unit end for end, gear end up. With a depth micrometer on a perfectly flat parallel bar
across the bearing bore, measure the distance to the shoulder in the bearing bore,
FIGURE 7-21.
FIGURE 7-20