Figure 9: IP66 with POE
Securing for IP66 (Ethernet & AC/DC power):
1. Slide the Ethernet cable through the threaded end of the cable sealing gland, with
Orange O-Ring installed.
2. Slide the 2, 20 AWG power wires through the back side of the cable sealing gland.
3. Measure approximately 4.5 inches of cable slack from the end of the cable to the
rubber grommet of the sealing gland. Use a scale to measure the length.
4. Attach one open end wrench onto the flange of the cable gland and tighten the
compression nut, with the second open wrench, to approximately 50-55 in-lbs. of
torque.
5. Assemble a new RJ45 head to the Cat 5 Ethernet Cable.
6. Assemble a mating power connector to the 2 AC or 2 DC power cables.
Figure 10: IP66 with Ethernet and AC/DC Power
Securing for IP66 (Analog & AC/DC Power – ZNT6-Hxx1 and ZNT6-Hxx2 Only)
1. Slide the Coax cable through the threaded end of the cable sealing gland, with
Orange O-Ring installed.
2. Slide the 2, 20 AWG power wires (and any RS-485 wires) through the back side of
the cable sealing gland.
3. Measure approximately 4.5 inches of cable slack from the end of the cable to the
rubber grommet of the sealing gland. Use a scale to measure the length.