Ganz Thermal Series Specifications are detailed below in Table 3.
Table 3: Ganz Thermal Series Specification Quick Reference Table
Focal Plane Array
Sensor Type
Uncooled VOx Microbolometer
Array Format
320x240 (ZNT6-Hxx1 Series)
640x480 (ZNT6-Hxx2 Series)
Pixel Pitch
17
µ
m
Spectral Band
8 - 14
µ
m (LWIR)
Sensitivity (NEDT) @ f/1.0
< 50 mK at f/1.0
Video
Frame Rate
Configurable for up to 30 Frames Per Second (fps)
or Fixed at 9 fps
Format
Analog: NTSC/PAL
IP: H264/MJPEG
Gain/Level Control
Automatic
4X Digital Zoom
1X-4X; 0.25X increments
Image Display
White Hot, Black Hot, Color, Invert/Revert
Symbology
On screen display with date, time, and user
defined text
Zoom
4x Digital Zoom with ePan/eTilt
Image Processing
Image Contrast Enhancement (ICE) for superior
performance
Communication Interface
Protocols
IP: ONVIF
™
Conformant (v 2.0 / Profile S), RTP,
RTSP, TCP, UDP, DHCP, FTP, HTTP, and NTP
Analog: PELCO-D
Interfaces
IP: Ethernet (10/100 Base T), RJ-45
Analog: RS-485
Security
802.1X Network Access Control and HTTPS
Electrical
Voltage
12-24 V DC, 24V AC, 802.3af Power Over
Ethernet (PoE)
Power
<12.95 W with Heater
Environmental
Operating Temperature
-40°C to +60°C (-40°F to 140°F)