Status LEDs
G&D VisionXS-C-TypeC-UHR ·
87
English
LEDs on the back panel
Area
Color
Status
Meaning
Transmission
green
on
Logged on at G&D remote station.
yellow
on
Communication with a G&D remote station has been
established.
blinking
Connection to a remote station/network switch
established.
red
an
Cable plugged into port that is not activated.
Unlock the port with a feature key.
off
Connection to remote station has not been
established.
Network
green
on
The connection to the network has been
successfully established.
yellow
on
A connection could not be established.
Pwr
green
on
The KVM extender is supplied with voltage and the
device software has been started successfully.
yellow
on
The KVM extender is supplied with voltage.
blue
on
On as soon as the LED has been activated via
web application.
off
The KVM extender is not supplied with voltage.
Service
Pwr
Transmission 2
Transmission 1
Main Power
Red. Power
Network
Main Power
Red. Power